Figure 32: Complete communication wiring
TO HOME
AUTOMATION
SYSTEM
NOTE:
Digital I/O must be connected to a dry contact relay.
Analog flame and light input through 0 - 10 volt DC
signal scaled as follows:
Low = 1 volt
High = 10 volts
NOTE:
•
When a signal has been supplied by the home automation system, the fireplace control will
repeat the signal every 2 hours or until a new command has been received.
•
Leave the wall switch on the “Remote” setting when using home automation.
The home automation feature supplied with this fireplace is
capable of controlling the flame and light on/off function with
the use of a dry contact relay common to home automation
systems. Furthermore, the flame and light level may be modu-
lated from high to low using the
0 - 10 volt analog output available on most home automation
systems.
Figure 33 shows the wire designations required to connect the
fireplace to a home automation system.
Home Automation
Figure 33: Home automation wiring.
TO FIREPLACE
5056.42523D2
18
TCWS38Dver2_140817-44