This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent
direct vent pipe, Selkirk Direct-temp vent pipe or ICC Exceldirect vent pipe
with a 5” inner pipe and an 8” outer pipe. For part numbers see the table of
venting components on page 29 of this manual. This vent can only be used
as a side wall termination.
1. Locate the power vent termination following the clearance to combustible table(Pages
20-22), venting confi guration diagram (Fig. #1 & 2), and terminal location diagram (Fig.
#3).
2. Cut and frame a 14 5/8” wide by 14 7/8” high opening. For standard up and out
installations, the opening should be 3/4” lower than the minimum specifi ed in Fig. #2.
Height of the opening will vary with each installation. See Fig. #5.
3. Attach the power vent terminal, by securing the outer fl anges on the perimeter of the
terminal to the outside wall; ensure that the terminal is the right way up (exhaust at the
bottom). Once secured to the building, the outer fl anges may be covered with siding/
stucco/etc. up to the level of the perimeter edge. As per local building codes. See Fig. #6.
4. Determine desired amount of exterior power vent protrusion, and fasten mounting
fl ange with supplied fasteners. Silicone joint after installation. See Fig. #30 and 31.
5. For wall thicknesses 7 1/2” or less, install the inner wall plate supplied over the terminal
as shown in Fig. #6 and secure to the framing. See Fig. #7.
CAUTION:
The adjustable vent restrictor located
on the underside of the fi rebox top
must be fully open.
CAUTION:
This terminal is designed to be fl ush,
or protruding to the fi nished outside
wall. Under no circumstances
should this terminal be recessed
into the wall past this point.
(Fig. #8)
Horizontal (Side Wall) Venting
23
TCWS.54CSTE 080713-68