12”
9 5/8”
12”
74 1/4"
55 1/4"
74 1/4"
22 1/16"
11 5/16"
5/8"
80 5/8"
46 1/4"
33"
114"
74 1/4"
INCLUDING SHEETROCK
NON-COMBUSTIBLE RECESSED
INSTALLATION DETAIL
NON-COMBUSTIBLE BOARD DETAIL
MINIMUM COMBUSTIBLE
FRAMING DIMENSIONS
IF THE BACKER BOARD IS NOT TO BE
FINISHED WITH OTHER NON-COMBUS-
TIBLE MATERIAL SUCH AS TILES, IT IS
RECOMMENDED THAT TOP SECTIONS
OF BOARD SUPPLIED WITH FRAMING KIT
BE REPLACED WITH A SINGLE SHEET OF
NON-COMBUSTIBLE BOARD. TAPED AND
MUDDED JOINTS MAY CRACK DUE TO
THE ELEVATED TEMPERATURES
.
FULL SHEET OF A NON-
COMBUSTIBLE MATERIAL
(NOT INCLUDED IN KIT)
Fig. #9A
Fig. #9
Fig. #10
Fig. #11
NON-COMBUSTIBLE
MATERIAL MUST EXTEND
12" ABOVE, 9 5/8" TO THE
SIDES AND 12” BELOW THE
FRAMING EDGES.
NON-COMBUSTIBLE
BOARD
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
STEEL STUDS
NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
NON-COMBUSTIBLE
BOARD
9
TCWS.54CE2 200810-40