CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to
cool before servicing appliance. It is recommended that the fi replace and its venting
should be inspected at least once a year by a qualifi ed service person.
Glass Panel:
Warning:
Do not operate fi replace with glass panel removed, cracked or broken. Replace-
ment of the glass panel should be done by a licensed or qualifi ed service person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass
becomes cracked or broken it must be replaced before using the fi replace. Replacement glass
can be obtained from your nearest Town & Country Fireplaces
TM
dealer. The size required
is 52" x 16" x 5mm. Use ceramic glass only.
Do not substitute with any other type.
To remove broken glass, remove window frame as noted in "Window Frame Removal"
section.
Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull the
top edge of the glass out of the frame fi rst, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker bead of
gasket faces the fi replace.
Re-install glass retaining clips.
Annual Inspection:
a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for
soot buildup. If excessive buildup of soot is present, have a qualifi ed service person inspect
and adjust unit for proper combustion. Clean logs and burner with a brush or vacuum
cleaner, paying close attention to burner ports. Replace ember material if needed.
b) Check the pilot system for proper fl ame size and operation. Clean pilot free of soot, dust
or any other deposits. (See Fig. #53)
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If
the venting is disassembled for cleaning, it must be properly assembled and re-sealed.
Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be
maintained in good condition.
e) Check and replace batteries as needed.
Note:
The appliance area must be kept clear and free from combustible materials, gasoline
and other fl ammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fi replace glass cleaner.
b) Exterior fi nish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fi replace.
Do not clean glass when hot.
APPENDIX
PILOT FLAME
FLAME SENSOR
ELECTRODE
PILOT
Fig. #53
30
TCWS.54CE 200810-40
Maintenance
Summary of Contents for TCWS.54CE2
Page 38: ...38 TCWS 54CE 200810 40 ...