36"
24"
(91.5 cm)
(61 cm)
See Fig #30b
Vent System Components
Town & Country
12" Pipe Length .................................................... TCVT.811X12
18" Pipe Length .................................................... TCVT.811X18
24" Pipe Length .................................................... TCVT.811X24
48" Pipe Length .................................................... TCVT.811X48
12" Adjustable Pipe Length ................................... TCVT.811X12ADj
45° Elbow ............................................................. TCVT.811XLB45
Wall/Offset Support .............................................. TCVT.811XOS
*
A minimum of 1 support every 4’ must be used.*
Roof Termination Kit ............................................. TCVT.RTA
Wall Shield/Ceiling Firestop .................................. TCVT.THIMA
Roof Flashing, Adjustable ..................................... TCVT.811FLADj
Roof Flashing, Flat ............................................... TCVT.811FLFLT
Roof Flashing, Steep ............................................ TCVT.811FLSTP
or any flashing that fits 11" pipe
VENT TERmINAl mINImUm ClEARANCES
TO ADJACENT STRUCTURES
Fig. #30
Fig. #31
Minimum clearances to the vent terminal must be maintained as shown
in figure #33 & 34. Measure clearances to the nearest edge of termina-
tion hood.
NOTE: Vent terminal must not be
recessed
NOTE: lOCAl CODES OR REGUlATIONS mAY REQUIRE
DIFFERENT ClEARANCES.
Terminal to Sloped Roof
Pitch Table
(minimum)
ft
m
Flat to 6/12
1.00
0.30
Over 6/12 to 7/12
1.25
0.38
Over 7/12 to 8/12
1.50
0.46
Over 8/12 to 9/12
2.00
0.61
Over 9/12 to 10/12
2.50
0.76
Over 10/12 to 11/12
3.25
0.99
Over 11/12 to 12/12
4.00
1.22
Fig. #30b
20
TCWS.54CE 110110-40
Vent Terminal Clearance