5056.42562
Figure 24:
Control box
components.
Figure 23: Junction box wiring.
Figure 22: Access to firebox.
The gas control system is located on the right hand side of the firebox behind an access
panel and the decorative firebox panel (if installed). The fireplace is operated via a wall
control and a hand held remote control unit.
The wall control is connected to the fireplace by a 40 ft. communication cable supplied
with the fireplace. The communication cable can be extended with an optional 40 ft.
extension kit.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 22).
4. Connect 110 V. AC electrical supply to the wires installed inside the junction box
(Figure 23). The fireplace is rated at 110 volts, 60Hz, 0.25A. The optional power vent
kit is rated at 115 volts, 60Hz, 1.8A.
The electrical wires can be accessed from both inside and outside the junction box
by removing one of the two small access panels (Figure 23 & Figure 24) .
5. Attach the wall switch (Figure 25) to the framing in the desired location (40 ft is sup-
plied with fireplace).
6. Route the wall switch control cable (supplied) as required to the wall switch
(Figure 26).
7. Attach one end of the wall switch control cable to the wall control (Figure 26), and
the other end to the interface board (Figure 24).
FIREBOX ACCESS PANEL
INTERFACE BOARD
MODULE
JUNCTION BOX
REGULATOR
BOARD
TRANSFORMER
VACUUM
SWITCH
GAS CONNECTOR
OUTER ACCESS PANEL
INSIDE ACCESS
PANEL
WALL SWITCH
CONNECTOR
JUNCTION BOX
POWER
VENT
SWITCH
Electrical
Note: Installation must be performed by a qualified
installer, service agency or gas supplier.
8. Insert the 4 supplied “AA” batteries
into the battery pack of the wall switch
(Figure 27).
9. If not already installed, install the burner
using the instructions supplied with the
burner kit.
10. Turn on the gas supply and check that all
connections are tight and leak free.
11. Turn on gas and electrical supplies.
12. Move the center button on the wall con-
trol (Figure 25) to the “ON” position. The
igniter will start to spark. After a short
delay, the pilot will light followed by the
main burner.
15