5056.42562
5 7/8
18 3/4
Figure 12: Non-combustible board within frame.
18 3/4"
5"
63 1/2"
81 1/8"
26 5/8"
81 1/8"
37 11/16"
1/2"
63 1/2"
114 11/16"
RANGE
32 13/16"
to
34 9/16"
RANGE
34 13/16"
to
36 5/16"
RANGE
1/32"
to
3 1/2"
14 5/8"
FRAMING
LINTEL
Figure 14: TC54 Minimum Combustible Framing.
NON-COMBUSTIBLE BOARD DETAIL
NON-COMBUSTIBLE BOARD (OR
OTHER NON-COMBUSTIBLE
MATERIAL) MUST EXTEND 18 3/4"
ABOVE AND 5" TO THE SIDES OF
THE FRAMING EDGES.
NON-COMBUSTIBLE BOARD
MINIMUM COMBUSTIBLE FRAMING DIMENSIONS
NOTE: Fireplace should be in its fi nal location before framing.
NON-COMBUSTIBLE RECESSED
INSTALLATION DETAIL
NON-COMBUSTIBLE
BOARD
If fi nishing the wall above the unit with paint,
the framing kit shipped with the unit should
be discarded. Use full sheets of calcium
silicate board or equivalent and full length
metal studs to fi nish and frame around the
unit.
Calcium silicate board is a high grade mate-
rial with cement, quartz and natural minerals
as the main raw materials. (Note: Calcium
Silicate is 1/2” thick)
CAUTION: Calcium Silicate board can be
damaged if dropped or struck. Handle with
care. Inspect board prior to installation and
do not use if cracked.
NOTE: It is recommended to pre-drill mount-
ing holes in the board prior to securing to
the framing. This will prevent the board from
cracking.
This fi replace may be recessed up
to a maximum depth of 4 1/2”. This
recess must be constructed from
non- combustible material.
Finishing material must not pro-
trude past framing fl anges under
ANY circumstance. The safety
screen and the window, with trim
fi tted, must be able to move freely.
Figure 11: Non-combustible board
location.
Figure 13: Recessed detail.
10
TC54D _111215-44