11
TC42_NG06D_060117-16
5056.426D2-A
For complete valve installation instructions, refer to the
instruction book included in the SIT conversion kit.
10. Open the air shutter by following the steps in the Burner Flame Adjustment on page 12.
11. Complete the gas valve conversion from natural gas to propane gas according to the instructions included
in the SIT propane gas conversion kit.
12. Once conversion is complete, fi ll out and place gas conversion label (Figure 24) to inside of control box
where it will not be affected by the heat of the fi rebox.
Pilot
adjustment
band
Figure 22: Pilot band in natural gas position.
Hole in sliding band
indicates propane
gas configuration
Figure 23: Pilot band in propane gas position.
Cet appareil a été converti en gaz propane
Numéro d'assemblage
j
m
a
Firme
Adresse
l'entreprise désignée
ci-dessus accepte la
responsabilité que cette
conversion a été
correctement faite.
Kit Number
dd
mm
yy
Company
Address
The above accepts the
responsibility that this
conversion has been
properly performed.
This appliance was converted to propane gas
5052.52001-B
5052.52001-B
Figure 24: Propane conversion label.