tousek TURN 10 Installation And Operating Instructions Manual Download Page 11

Motor number (Type plate):

Other components:

Declaration of incorporation

In  compliance  with  EC  Machine  Directive  2006/42/EC, 

Annex II B for the installation of an incomplete machine.

We  hereby  declare  that  the  following  product,  as  well 

as its version, put by us into circulation, complies with 

the essential requirements of the Machinery Directive 

(2006/42/EC), due to its design and type of construction.

The validity of this declaration will cease in case of any 

unauthorized modifications to the products.

The product: 

Swing gate operator  

TURN 10, -20, TURN UP 1, -2

is developed, designed and manufactured in accordance 

with:
Machinery Directive 2006/42/EG

Low Voltage directive 2006/95/EG

Electromagnetic compatibility 2004/108/EG

Applied and used standards and specifications:

EN ISO 13849-1, PL-„c“

 

EN 60335-1

 

EN 60335-2-103

 

EN 61000-6-3

 

EN 61000-6-2

Following  requirements  of Annex  I  of  the  EC  Directive 

2006/42/EC are met:

1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 1.3.4, 

1.3.7, 1.5.1, 1.5.4, 1.5.6, 1.5.8, 1.7

The relevant technical documentation is compiled in 

accordance with Annex VII, Part B of the EC Machinery 

Directive 2006/42/EC.

We undertake to submit it in electronic form and within a 

reasonable time to the market surveillance authorities in 

response to a duly substantiated request.

 

TOUSEK  Ges.m.b.H., A1230  Wien,  Zetschegasse  1, 

 

Austria

is authorized to compile  the technical documentation.

The incomplete machine cannot be put into service, until it 

is determined that the machine, into which the incomplete 

machine has to be inserted, complies with the the Machine 

Directive 2006/42/EC.

Eduard Tousek, CEO 

 

Vienna, 01. 01. 2013

EC Declaration of Conformity

In  compliance  with  EC  Machine  Directive  2006/42/EC, 

Annex II, Part 1 A.

When the described operators are connected to a gate they 

form   a machine in the sense of the EC Machine Directive.

Relevant EU directives:
Construction Products Directive 89/106/EWG

Machinery Directive 2006/42/EG

Electromagnetic compatibility  2004/108/EG

Low Voltage directive 2006/95/EG

We hereby declare that the following product, in the version 

put by us into circulation, complies with the essential requi

-

rements of the Directives mentioned above. The validity 

of this declaration will cease in case of any unauthorized 

modifications to the products.

Product:

Gate description

Motor description

The incomplete machine cannot be put into service, until it 

is determined that the machine, into which the incomplete 

machine has to be inserted, complies with the the Machine 

Directive 2006/42/EC.

Installation company

Address, ZIP code, Place

Date/ Signature

Summary of Contents for TURN 10

Page 1: ...Installation and Operating Instructions Swing gate operator TURN 10 TURN 20...

Page 2: ...proper function of the gate facility and the safety devices has to be checked Place warning signs and notes of the valid regulations to indicate danger areas With each installation the identification...

Page 3: ...gate operators A key for emergency release permits the manual opening of the gate in case of e g power failures At rising gate entrances additionally the optional hinge joint has to be mounted Techni...

Page 4: ...the open and closed gate positions If this is not the case such stopping devices have to be installed or the Tousek piston rod stroke limiting device has to be used The spindle may not be fully exten...

Page 5: ...point centered to gate leaf Opening to the INSIDE pivotal point not centered inside to gate leaf Mounting at larger columns Mounting measures with different swing gate situations Special case using a...

Page 6: ...t Before mounting please grease the mounting parts at their pivot points as well as the push rod in extended position Motor sided mounting Put the operator on the assembly part 2 Then insert the cylin...

Page 7: ...regarding the force adjustment have to be in compliance with the effec tive rules 2c Electric connections and force adjustment Installation The gate facility must be turned off from power supply when...

Page 8: ...release of the operator at power failure Swing gate operator TURN 10 TURN 20 should it be necessary to release the operator e g in case of power failure please proceed as follows Turn off power suppl...

Page 9: ...r and general danger areas of the motorised gate have to be secured In this context please follow the EU Machine Directive accident prevention rules and laws as well as applying EU and national standa...

Page 10: ...brackets 5 Dimensioned sketch Swing gate operator TURN 10 TURN 20 assembly part spindle sided assembly part motor sided measures and technical modifications subject to change 520 617 303 402 940 1141...

Page 11: ...ic form and within a reasonable time to the market surveillance authorities in response to a duly substantiated request TOUSEK Ges m b H A1230 Wien Zetschegasse 1 Austria is authorized to compile the...

Page 12: ...at Tousek GmbH Germany D 83395 Freilassing Traunsteiner Stra e 12 Tel 49 8654 77 66 0 Fax 49 8654 57 196 info tousek de Tousek Benelux NV BE 3930 Hamont Achel Buitenheide 2A 1 Tel 32 11 91 61 60 Fax...

Reviews: