tousek
/ E_TPS-20_03 / 30. 08. 2016
- 29 -
ISD
FE
Radio receiver
(socket FE)
•
On the 11-pin socket (FE) a radio receiver (e.g.
BT40SO230V, RS433SO230V or RS868SO230V) can
be plugged. For a greater range use an external antenna.
The function of the radio receiver is identical to the
impulse switch.
Induction loop detector
(socket ISD)
•
On the 11-pin socket (ISD) an induction loop detector
ISD5 can be plugged.
The function of the detector is identical to the impulse
switch.
Radio receiver and induction loop detector
Sockets of TPS 20 PRO
3.6 Other connections of TPS 20 PRO
Sliding gate operator TPS 20 PRO
4.
Sockets of TPS 20 PRO
Sliding gate operator TPS 20 PRO
Decoupled Impulse switch
(terminals X1: 35/36)
Other connections
•
These input terminals are used for a far away impulse
switch. The function is identical to the normal impulse
switch input.
X1
35
36
„Permanent open“ switch
• The adjustment of
OPEN
in menu button-switches/
impulse button is required for the correct function. Closing
of the gate with the impulse switch is not possible with
this adjustment.
Decoupled „permanent open“ switch
(terminals X1: 35/36)
Other connections
• The “permanent open” contact is used for e.g. fire alarm
systems, weekly timers or porter signals. When the
contact is closed the door opens and remains in open
position (This situation can easily be detected by relay
K2). If the switch is opened again the pause time in au-
tomatic mode starts. The door closes after pause time.
X1
35
36
Induction loop input
(terminals X1: 9/1,9/2)
Other connections
•
For connecting the induction loop. The function is identi-
cal to the “permanent open” switch input.
For more information about induction loop and detector
see according manual.
X1
9/1
9/2