background image

Sponge

Decorative 

bolt

Fastening 

fixture

*  There are 

fastening fixtures 

on both ends.

Wall

Sponge

Number sticker

Reverse side of upper lid

Upper lid

Fastening fixture

Packing

Decorative bolt

Fastening fixture 

assembly

Slip washer

*1: DC Dry Battery type flashes; 

AC type stays lit

Check for water 

leaks here

Fastening bolt

Fastening hole

Around 

8 mm

Controller

Press

Power wire

Shutoff valve

CAUTIO N

Prohibited

Do not remove the terminal 

block cover covering the 

terminal block

Touching the terminal block 

may cause electrical shock.

Controller

<Connecting the power wire>

Terminal block

cover

Power

wire

Terminal

block

Terminal block cover

ON

1 2 3 4

Waterproof cover

Switch

Controller

The detection range is automatically adjusted when the power is turned on.

*  The photoelectric sensor's automatic detection range adjustment function 

operates soon after power is activated. If the photoelectric sensor lamp 

continues to flash or stay lit 

*1

 when the unit detects something other than a 

human, this means that the detection range is currently being adjusted. Be 

careful that the sensor is not triggered by a human before the lamp turns off.

*  If a human is detected when the lamp is flashing or lit 

*1

it will take longer to adjust the detection range. 

Adjustment is complete when the lamp turns off.

Hold the fastening fixture down from inside the 

urinal, then use a hex wrench (nominal 

designation 4) to loosen the decorative bolt.

Bring the decorative bolt to the outside. 

(Reference: Gap of approximately 8 mm)

While pressing the sponge attached to the rear 

surface of the upper lid against the wall, place 

the lid.

Use a hex wrench to turn the decorative bolt, 

then fasten the urinal unit and upper lid.

*  Be careful not to tighten the decorative bolt too 

strongly and crack the urinal unit or upper lid.

*  If there is a gap between the upper lid and 

urinal unit after fastening the upper lid, loosen 

the decorative bolt, then tighten both sides 

again equally until there is no gap.

*  Install only the upper lid that came packaged 

with the unit. The upper lid and urinal unit are 

manufactured together as a single unit. Using 

an upper lid other than the one packaged with 

the unit could cause looseness.

*  Use the numbers on the number stickers 

attached to the storage side surface of the 

urinal unit and the underside of the upper lid to 

check the combination.

If the fastening fixture is removed, refer to the 

diagram to the left for assembly.

Adjust the photoelectric sensor detection range

10

12

Install the upper lid

14

Configure preliminary flushing (continued)

13

Configure preliminary flushing

 (switch as needed)

13

Run the electric wire so 

that it does not hang over 

the top of the shutoff valve.

Be sure to turn the 
power on with water 
being supplied.

CAUTION

Key points

If the waterproof 

cover is removed, 

cover the controller.

CAUTION

Remove the waterproof cover.
Insert the alkaline battery into the battery box, then connect the controller 

connector and battery box connector.

* For 10 minutes after connecting the battery box, the LED flashes during 

photoelectric sensor detection to enable the detection status to be confirmed. 

The lamp does not flash even when it detects something after this 10 minute 

period.
Install the 

waterproof 

cover.

Controlle r

Waterproof cover

Controller

Battery box

Insert battery

 (DC Dry Battery type only)

9

Prohibited

Do not pull the battery box electric wires

Doing so may di sconnect the wires or  

terminals,  or cause fire or electrical sh ock.

CAUTION

Trigger the photoelectric sensor and confirm that the urinal flushes.

* AC type units will automatically flush the urinal immediately after electric current is applied. 

Confirm the above once automatic flushing is complete immediately after electric current is applied.

* If the photoelectric sensor flashes when it has not detected a human, this means that the 

photoelectric sensor is automatically adjusting the detection range. Wait until the lamp 

stops flashing. (See “      Adjust the photoelectric sensor detection range” for more details)

* If the urinal has a manual flush button, after confirming that the urinal flushes by 

photoelectric sensor detection, confirm that the urinal flushes when the button on the 

right side of the urinal is operated.

10

Manual

(Singapore

  Type only)

flush

button

Confirm that the urinal flushes

11

Sensor not flashing

Sensor detection

Flush

w/ button

Remove the waterproof cover.

Slide the controller up.

Open the setting switch cover on the 

controller, and turn switch 1 ON.

After setting the switch, return the 

waterproof cover, controller, and 

setting switch cover to their original 

positions.

*  Switches 2 through 4 have no effect 

on the preliminary flushing setting.

If switches 2 through 4 are mistakenly 

turned ON, be sure to turn them OFF.

*  The preliminary flushing switch 

is set to “OFF” by default.

After confirming that there are no pipe connection problems, supply water 

through the piping, and confirm that there are no water leaks in the connections 

between the piping and shutoff valve, and between the shutoff valve and valve.

Check for water leaks in the drainage connections

Take the power wire out of the 

switch box, pass it through the 

rear of the waterproof cover, 

and connect it to the two 

terminals (

 and 

).

*  Cut the power wire if it is too 

long.

*  Strip the gray covering on the 

power wire 25 to 30 mm from 

the end. This will make it 

easier to connect the power 

wire and terminal block.

CAUTION 

Confirm that no current is applied before connecting the power wire

Failure to do so may cause electrical shock.

The power supply terminal block and primary power supply must be connected by a qualified person only

Failure to do so may cause a malfunction or electric shock.

When inserting the power wire (VVF) into the terminal block, 

insert the grounded side of the wire into the white line side, 

and the non-grounded side of the wire into the black line side

Failure to do so may cause fire.

Connect the power wire

 (AC type, e water+ type)

8

REQUIRED

WARNING

When removing the power wire, always be sure to press the white part 

on the surface of the power supply terminal block with a flat-head 

screwdriver, then remove the wire.

Pulling the power wire out with unreasonable force may cause damage to the controller.

REQUIRED

Black line

White line

<Removing the power wire>

After confirming that there are no pipe connection problems, supply water through the piping, and confirm that there 

are no water leaks in the connections between the piping and shutoff valve, and between the shutoff valve and valve.

Check for water leaks in the water supply connections

7

Around 25 to 30 mm

Around 10 to 15 mm

Summary of Contents for USWN900 Series

Page 1: ...normal Parts Names Useprohibitednearwater REQUIRED Always carry out construction work with at least two people Otherwise the installer may injure his or her lower back or drop the porcelain and damage it After construction be sure to give the product a test run and check that there are no water leaks in any part Not installing the product properly may cause water leaks that could result in floodin...

Page 2: ...Installation Meth od 220 240V AC electrical work is required only for the AC type Be sure to perform construction steps through prior to installing the urinal Install the drainage flange according to the included Work Instructions Install switch box Install shutoff valve Install drainage flange Install urinal unit Connect shutoff valve and valve Check for water leaks in water supply connections Co...

Page 3: ...nut too strongly and crack the urinal unit Be careful that the shutoff valve does not strike the urinal unit Fix the flange bolt to the lower part of the urinal with the washer large and nut The washer large and nut are packaged with the drainage flange The hex size of the nut is 13 mm A board ratchet wrench with a total length of 150 mm or less is recommended to tighten the nut Prohibited Pull th...

Page 4: ...nute period Install the waterproof cover Controller Waterproof cover Controller Battery box Insert battery DC Dry Battery type only 9 Prohibited Do not pull the battery box electric wires Doing so may di sconnectthe wires or terminals or cause fire or electrical sh ock CAUTION Trigger the photoelectric sensor and confirm that the urinal flushes AC type units will automatically flush the urinal imm...

Reviews: