![Toto USWN900 Series Installation Manual Download Page 3](http://html.mh-extra.com/html/toto/uswn900-series/uswn900-series_installation-manual_1139573003.webp)
To raise
How to carry the urinal
To lower
Insert a
piece
of metal
Quick fastener
Screwless conduit Ø19
(provided on-site)
Conduit connector (provided on-site)
Switch box (provided on-site)
Power wire
(provided on-site)
Front view (shutoff valve installed)
Wrap seal material
(G1/2)
Center line of the urinal
Construction
error ± 10 in
vertical/horizontal
directions
(Unit: mm)
Make sure the quick fastener
cover is locked, then fix it in place.
Rotate the quick fastener and
check the connection.
150 mm or less
Power wire
Shutoff valve
Lock
Quick
fastener
Flange
Use the quick fastener to connect the shutoff
valve and valve.
box.
<Installation Method>
If the O-ring is di rtied, damaged , or sticks out, it could ca use water leaks that
could result in flooding damage to property, s uch as household belongings.
Connect the shutoff valve and valve
Install the urinal unit (continued)
6
5
REQUIRED
Do not install the urinal unit from the drainage outlet side.
Doing so could cause water leaks from the drainage flange that could
result in flooding damage to property, such as household belongings.
2
Wrap seal material around the connector
and screw the shutoff valve in the direction
of the arrow.
* Work the shutoff valve
so that it is within the
construction error
tolerance level.
* Install the shutoff valve
parallel to the wall.
There may be cases
where parts touch the
porcelain and cannot
be installed.
①
Connect the power wire and switch box
to the conduit connector, pass the power
wire through the conduit, and pull it into
the switch box.
②
Fill the area around the switch box with mortar.
Install the switch box and backfill the foundation wall
Install the shutoff valve
Be sure to supply water
through the water supply
pipe to flush out any dirt
prior to installation.
Key points
3
4
Water supply position
Planar view
Parallel to wall
Parallel to wall 33±5m
m
± 10 mm in
horizontal direction
± 10 mm in
vertical direction
Install the back hanger to the location shown in the diagram.
Clean the area around the urinal drainage
outlet of dirt and water,
then attach the
seal ring to the urinal drainage outlet.
Align the centers of the urinal drainage
outlet and drainage flange, then hang
the urinal unit from the back hanger.
Be careful not to tighten the
nut too strongly and crack
the urinal unit.
Be careful that the shutoff
valve does not strike the
urinal unit.
Fix the flange bolt to the lower part
of the urinal with the washer (large)
and nut.
* The washer (large) and nut are
packaged with the drainage flange.
* The hex size of the nut is 13 mm.
A board ratchet wrench with a total
length of 150 mm or less is
recommended to tighten the nut.
Prohibited
Pull the power wire around 25 cm toward the
shutoff valve, in order to make it easier to
connect the power wire and terminal block.
Install the urinal unit
5
CAUTION
CAUTION
Planar view
Drill a pilot hole of around Ø3 at the
marked installation hole position.
* Drilling a pilot hole of around Ø3 will
make it easier to work.
Do not immediately fix the back hanger
with the three wood screws; instead,
temporarily fix it with the elliptic holes
only.
Attach the seal ring onto the urinal
for a trial at first,
hang the urinal from
the back hanger, adjust it to the indicated
position, then fix it in place. If the urinal
does not reach the indicated height,
loosen the back hanger's wooden
screws, then place a metal plate
between it and the wall to adjust it.
Refer to the
Installation Manual
attached to the urinal for information
on how to install
the quick fastener.
CAUTION
Insert the valve straight into the shutoff valve.
* Use a switch box for a single device
(no cover).
* A grounding wire is not needed, so
use a two-core power wire.
* Use a screwless conduit (nominal
designation, provided on-site).
* Leaving around 40 cm of slack outside
the box, wind the power wire inside the box.
Align the flanges on the shutoff valve and valve,
then insert the quick fastener.
* If the valve is not fully inserted, it will be impossible
to install the quick fastener.
Confirm that the flange is fully inserted into the
recess on the quick fastener, rotate it to the front and
rear, then check the connection between the shutoff
valve and valve.
If the quick fastener does not rotate
smoothly after connecting it, reconnect it
If the quick fastener is not connected properly,
water leaks could result in flooding damage to
property, such as household belongings.
Install the quick fastener properly, then
check visually or through other means.
REQUIRED
120mm
545mm
225mm
95mm
*3
280mm
485mm
*1 (size)
*2 (size)
*3 (size)
Use a level or other instrument to install the back
hanger so that its upper surface is level.
Measurement from
center of drainage
outlet *2
Elliptic holes
*1
*1
・