Toto RYOHAN TEL3GMY Installation Manual Download Page 7

STEP 

9   

-

STEP 

10

Install the Drain cup 

Remove the drain cup unit

2 .Turn the drain cup unit

clockwise (About 45 degrees)

 

1 .Pull the drain cup unit 

firmly to the drain part 

then release it.

 

3 .Pull the drain cup upwards

and out

Drain cup Unit

Main Drain

Body

 

 

 

 

If the drain cup is accidentally 

removed, begin the process over 

from the beinning. 

 

1.Insert the drain cup into the main drain 

body

3.Pull firmly on the drain cup unit, being 

careful not to remove it, then release it.

4. Push the drain cup unit in.

2

.

Turn the drain cup counter-clockwise 

making the cross-bar align with the 

notches in the angles.

 

Main Drain Body

Drain cup Unit

Cross-bar

Angle

Drain cup unit

Main Drain Body

Notch

Cross Bar

Angle

Notch

drain cup unit

Click! 

Push the drain

cup in until you

hear a “click”.

Pull Firmly

Drain cup Part

STEP 9

Attach the controller cover

STEP 10

Install the Drain

After checking the connectors are

securely attached, cover the controller.

Cover

Intall the main drain body, Gasket, washer, 

and Lock Nut in that order.

Gasket

     Washer

Lock Nut

Gasket

Main Drain Body

If the drain cup unit does not 

come out, put it back, and and 

while turning it clockwise once

again, slowly pull it out.

(Ryohan™

 only).

Summary of Contents for RYOHAN TEL3GMY

Page 1: ...utomatic Faucet This may cause damage or water leakage Never attempt to disassemble reassemble repair or modify the Automatic Faucet unless you are an electrician or qualified service person This may cause property damage or personal injury Do not disassemble Do not strike Specification EcoPower type Model number Power supply Battery life Item Detection range from the sensor 5 1 8 7 7 8 130 200 mm...

Page 2: ...er supply 2 Piping 3 Others When the water supply pressure is higher than 125PSI 862kPa be sure to reduce the pressure within a range of 20 to 80 PSI by using a pressure reducing valve available in the market Optimum working pressure range is from 14 5PSI to 125PSI 100kPa to 862kPa Make sure the water pressure is within this range Flush all water lines prior to installation Pay special attention s...

Page 3: ...ruction manual Others Allen wrench Size 1 16 2mm Spout Flexible tube and Open close tool are included RYOHAN Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose EcoPower type RYOHAN Screw φ3 mm 10 Helix Wall Mount Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose Helix Wall Mount 3 Phillip Screws Ø4x4...

Page 4: ...away any foreign matter such as dirt and sand trapped in the water supply pipe STEP 2 Remove the controller cover Pull and open the controller cover to the direction as shown right STEP 3 A Mount the water inlet bracket on the wall Mount the water inlet bracket on the wall and temporarily tighten the screws Make sure that the controller can be attached to the water inlet bracket Tighten the water ...

Page 5: ...cut the hose carefully with a cutter so the surface is square Insert the spout connecting hose into the flexible tube Clean the hose end after cutting Spout connecting hose Cutting length 4 inches or less 90 Spout connecting hose Flexible tube Remove the Permanent Flow Valve Pull out the pinch of the stop ring then remove the permanent flow valve Remove Permanent Flow Valve Stop Ring Pull out this...

Page 6: ... spout direction will need to be readjusted for proper operation Sensor Sensor light Back up battery connector white Sensor connector Green Caution STEP 8 Fasten the spout Ryohan Affix the spout by tightening the hexagonal nut Be sure to mount the faucet body with its spout tip directed toward the basin center Caution Spout position On the right side Drain Spout Basin center STEP 8 Install the spo...

Page 7: ...unit in 2 Turn the drain cup counter clockwise making the cross bar align with the notches in the angles Main Drain Body Drain cup Unit Cross bar Angle Drain cup unit Main Drain Body Notch Cross Bar Angle Notch drain cup unit Click Push the drain cup in until you hear a click Pull Firmly Drain cup Part STEP 9 Attach the controller cover STEP 10 Install the Drain After checking the connectors are s...

Page 8: ...atic Faucet may not operate properly 3 Adjustment of flow rate The flow controller regulates flow rate to 0 8gpm 3 L min there is no need to adjust the flow rate Use the Automatic Faucet with the stop valve fully opened However if you need to regulate the flow rate because the wash basin is small or that the water supply pressure is too strong adjust the flow rate by turning the stop valve clockwi...

Reviews: