STEP 

3-B

Mount the water inlet bracket on the wall

STEP 

3 -B

  

-

STEP 6

-

Connect the water supply lines to the water inlet bracket.

STEP 

4

Connect the controller to the water inlet bracket

-

Connect the controller to the water

    inlet bracket.

-

Attach it with a quick fastener.

Flexible hose

Copper tube

Flexible hose
Nut
Packing

not included

Copper tube

Nut

Friction ring

Cone washer

not included

Quick fastener

Water inlet bracket

Controller

STEP 5

Cut the spout connecting hose if necessary

-

Cut the spout connecting hose to

    the appropriate length.

      If the spout connecting hose is

        too long, cut it to proper length.

        Do not cut the hose more than

        4 inches.

        Be sure to cut the hose carefully

        with a cutter, so the surface

        is square.

-

Insert the spout connecting hose

    into the flexible tube. 

Clean the hose

end after cutting.

Spout connecting

hose

Cutting length:

4 inches or less

90

Spout connecting

hose

Flexible tube

¤

Remove the Permanent Flow Valve

Pull out the pinch of the stop ring, 

then remove the permanent 

flow valve

Remove

Permanent Flow Valve

Stop Ring

Pull out 

this pinch

STEP 6

Connect the spout connecting hose to the controller

-

Insert the spout connecting hose

    into the controller.

-

Fasten the hose with the hose

clamp. 

●Check that the spout connection

hose is firmly in place.

 

●Do not bend the spout connection 

hose. 

 

The hose clamp should be attached

at the specified position. 

●The spout connection hose must be

fastened with the hose clamp.  

Spout connecting 

hose

Hose

Clamp 

Fit the hose clamp over the hose adaptor. 

Caution

Summary of Contents for RYOHAN TEL3GMY

Page 1: ...utomatic Faucet This may cause damage or water leakage Never attempt to disassemble reassemble repair or modify the Automatic Faucet unless you are an electrician or qualified service person This may cause property damage or personal injury Do not disassemble Do not strike Specification EcoPower type Model number Power supply Battery life Item Detection range from the sensor 5 1 8 7 7 8 130 200 mm...

Page 2: ...er supply 2 Piping 3 Others When the water supply pressure is higher than 125PSI 862kPa be sure to reduce the pressure within a range of 20 to 80 PSI by using a pressure reducing valve available in the market Optimum working pressure range is from 14 5PSI to 125PSI 100kPa to 862kPa Make sure the water pressure is within this range Flush all water lines prior to installation Pay special attention s...

Page 3: ...ruction manual Others Allen wrench Size 1 16 2mm Spout Flexible tube and Open close tool are included RYOHAN Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose EcoPower type RYOHAN Screw φ3 mm 10 Helix Wall Mount Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose Helix Wall Mount 3 Phillip Screws Ø4x4...

Page 4: ...away any foreign matter such as dirt and sand trapped in the water supply pipe STEP 2 Remove the controller cover Pull and open the controller cover to the direction as shown right STEP 3 A Mount the water inlet bracket on the wall Mount the water inlet bracket on the wall and temporarily tighten the screws Make sure that the controller can be attached to the water inlet bracket Tighten the water ...

Page 5: ...cut the hose carefully with a cutter so the surface is square Insert the spout connecting hose into the flexible tube Clean the hose end after cutting Spout connecting hose Cutting length 4 inches or less 90 Spout connecting hose Flexible tube Remove the Permanent Flow Valve Pull out the pinch of the stop ring then remove the permanent flow valve Remove Permanent Flow Valve Stop Ring Pull out this...

Page 6: ... spout direction will need to be readjusted for proper operation Sensor Sensor light Back up battery connector white Sensor connector Green Caution STEP 8 Fasten the spout Ryohan Affix the spout by tightening the hexagonal nut Be sure to mount the faucet body with its spout tip directed toward the basin center Caution Spout position On the right side Drain Spout Basin center STEP 8 Install the spo...

Page 7: ...unit in 2 Turn the drain cup counter clockwise making the cross bar align with the notches in the angles Main Drain Body Drain cup Unit Cross bar Angle Drain cup unit Main Drain Body Notch Cross Bar Angle Notch drain cup unit Click Push the drain cup in until you hear a click Pull Firmly Drain cup Part STEP 9 Attach the controller cover STEP 10 Install the Drain After checking the connectors are s...

Page 8: ...atic Faucet may not operate properly 3 Adjustment of flow rate The flow controller regulates flow rate to 0 8gpm 3 L min there is no need to adjust the flow rate Use the Automatic Faucet with the stop valve fully opened However if you need to regulate the flow rate because the wash basin is small or that the water supply pressure is too strong adjust the flow rate by turning the stop valve clockwi...