Toto RYOHAN TEL3GMY Installation Manual Download Page 4

Install 
the drain

8) Confirm with Set-up

Diagram and install the

spout (Wall Mount only)

Installation Procedure

8

Fasten the spout with tool

STEP 

?

STEP 

3-A

Not included

1

Water supply

pipe

3

Mount the two water inlet

bracket on the wall

4

Connect the controller

to the water inlet bracket

7

Attach the connector

to the controller

2

Remove the controller cover

5

Cut the spout

connecting hose

if neccessary

6

Connect the spout

connecting hose

to the controller

9

Attach the controller cover

STEP

1

Water supply pipe

Before installing the faucet, be sure to thoroughly flush away any foreign matter

such as dirt and sand trapped in the water supply pipe. 

STEP 

2

Remove the controller cover

Pull and open the controller cover to the

direction as shown right.

STEP 

3-A

Mount the water inlet bracket on the wall

?

Mount the water inlet bracket on the

    wall and temporarily tighten the screws. 

?

Make sure that the controller can be

    attached to the water inlet bracket.

?

Tighten the water inlet bracket with

    the three self tapping screws.

    Note: Anchors for wall may be needed. 

Be sure to mount the water

inlet bracket in the correct

direction. 

Otherwise, the strainer on the

water inlet bracket will be

inaccessible for cleaning.

Caution

To be continued on the back

Self tapping screw

Water inlet

bracket

Wall anchors

(not included)

IN

10

Pull

Controller Cover

STEP  2

Summary of Contents for RYOHAN TEL3GMY

Page 1: ...utomatic Faucet This may cause damage or water leakage Never attempt to disassemble reassemble repair or modify the Automatic Faucet unless you are an electrician or qualified service person This may cause property damage or personal injury Do not disassemble Do not strike Specification EcoPower type Model number Power supply Battery life Item Detection range from the sensor 5 1 8 7 7 8 130 200 mm...

Page 2: ...er supply 2 Piping 3 Others When the water supply pressure is higher than 125PSI 862kPa be sure to reduce the pressure within a range of 20 to 80 PSI by using a pressure reducing valve available in the market Optimum working pressure range is from 14 5PSI to 125PSI 100kPa to 862kPa Make sure the water pressure is within this range Flush all water lines prior to installation Pay special attention s...

Page 3: ...ruction manual Others Allen wrench Size 1 16 2mm Spout Flexible tube and Open close tool are included RYOHAN Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose EcoPower type RYOHAN Screw φ3 mm 10 Helix Wall Mount Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose Helix Wall Mount 3 Phillip Screws Ø4x4...

Page 4: ...away any foreign matter such as dirt and sand trapped in the water supply pipe STEP 2 Remove the controller cover Pull and open the controller cover to the direction as shown right STEP 3 A Mount the water inlet bracket on the wall Mount the water inlet bracket on the wall and temporarily tighten the screws Make sure that the controller can be attached to the water inlet bracket Tighten the water ...

Page 5: ...cut the hose carefully with a cutter so the surface is square Insert the spout connecting hose into the flexible tube Clean the hose end after cutting Spout connecting hose Cutting length 4 inches or less 90 Spout connecting hose Flexible tube Remove the Permanent Flow Valve Pull out the pinch of the stop ring then remove the permanent flow valve Remove Permanent Flow Valve Stop Ring Pull out this...

Page 6: ... spout direction will need to be readjusted for proper operation Sensor Sensor light Back up battery connector white Sensor connector Green Caution STEP 8 Fasten the spout Ryohan Affix the spout by tightening the hexagonal nut Be sure to mount the faucet body with its spout tip directed toward the basin center Caution Spout position On the right side Drain Spout Basin center STEP 8 Install the spo...

Page 7: ...unit in 2 Turn the drain cup counter clockwise making the cross bar align with the notches in the angles Main Drain Body Drain cup Unit Cross bar Angle Drain cup unit Main Drain Body Notch Cross Bar Angle Notch drain cup unit Click Push the drain cup in until you hear a click Pull Firmly Drain cup Part STEP 9 Attach the controller cover STEP 10 Install the Drain After checking the connectors are s...

Page 8: ...atic Faucet may not operate properly 3 Adjustment of flow rate The flow controller regulates flow rate to 0 8gpm 3 L min there is no need to adjust the flow rate Use the Automatic Faucet with the stop valve fully opened However if you need to regulate the flow rate because the wash basin is small or that the water supply pressure is too strong adjust the flow rate by turning the stop valve clockwi...