14
ENGLISH
TROUBLESHOOTING
Problem
Operating
Solution
No soap comes out
Green LED flashing
Fill tank with liquid soap.
Red LED flashing
Battery is low
Replace batteries.
Green LED solid on
Clean the pump unit.
Soap won’t
stop running
-
Sensor window is dirty
Clean sensor window.
-
There is an obstruction in front of sensor window
Remove the obstruction.
Soap comes out
unexpectedlly
Sensor window is dirty
Clean sensor window.
Soap will be automatic dispersed after 48 hours of non-usage to
prevent clogging.
-
Amount of dispensed
soap is small
Pump is not working correctly
Clean the pump unit.
SPECIFICATIONS
Power supply
Sensor detection range
5-7/8"±5/8"(150mm±15mm)
Ambient temperature
32~104°F (1~40°C)
Humidity
Max. 90% RH
Cause
Soap is low
Pump is sticking
-
Clean sensor window.
-
Sensor cable is disconnected
Connect cable.
-
Remove the obstruction.
Sensor window is dirty
There is an obstruction in front of sensor window
-
Connect cable.
-
Tube is disconnected
Connect tube.
-
Plug in the AC adapter.
Power supply (AC adapter or battery box) is disconnected
AC adapter is not plugged in
-
-
-
Change to TOTO
approved liquid soap.
Soap viscosity is high
Tank capacity
50 oz (1500ml)
Soap volume
0.03-0.04 oz (0.8-1.2ml)
Type
DSE101EEB
AC
AC 100~240V
DSE101EEC
AC
AC 100~240V
AC adaptor
GPBSW0601500WD00
GPUSW0601500WD00
Input
100-240 VAC, 50/60 Hz
Output
6,0 VDC, 1500 mA
CAUTION
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.
DSE101KE
DC
4×D 1.5V alkaline batteries
/
/
/
Summary of Contents for DSE101EEB