background image

 

XSDC 601-01 

 

5. Installation 

 

 

Personal

safety devices must be

 

 

 

 

 

used  during  this operation. 

 

 

 

5.1 Transport 

The refrigerator cabinet is shipped on a pallet and

 

 

   

 

   

 

 

protected by its packaging. 

The refrigerator cabinet should always and only be

 

 

 

 

 

 

   

transported in a ​vertical​ position 

(indicated Up-Down on the packaging) (see figure). 

 

Installation and start-up must be

 

 

 

 

 

performed

by

qualified

and

 

 

 

 

authorized personnel only. 

 

5.2 Environmental specifications. 

 

When positioning the equipment, keep in mind that its operation is guaranteed only in environmental

 

 

 

 

   

 

   

   

 

   

 

conditions with a temperature of +18°C to +43°C. 

 

5.3 Positioning 

 

Check the suitability of the electrical plug installed (SHUKO) according to current national

 

 

   

 

 

 

 

 

   

 

 

laws. Replace the plug if not in compliance; the replacement must be done by qualifed

 

 

 

   

   

 

 

 

 

 

 

 

 

personnel. Check that the mains voltage corresponds with that of the REFRIGERATOR

 

 

 

 

 

 

 

 

 

 

 

 

CABINET as reported on the label. Before positioning the equipment, put on safety clothing

   

 

 

 

 

 

 

 

 

 

 

 

 

and gloves for moving it since the metal parts could be sharp. Position the product in a

 

 

 

   

 

 

 

 

 

 

 

 

 

     

clean, dry and well-ventilated area. The refrigerator is set for operation in environments

 

 

 

 

 

 

   

 

 

   

 

where the temperature is b18°C and +43°C (Tropicalized Compressor) -Climate

 

 

   

 

 

 

 

 

 

 

Class T -. The equipment should be located far from heat sources and in places with

     

 

 

 

 

 

 

 

 

 

   

 

 

sufficient ventilation. Do not install the equipment in places where there are explosive

 

 

 

 

 

 

   

 

 

 

 

 

and/or corrosive gases/powders. Make sure the equipment is level and on flooring that is

 

 

 

 

 

 

   

 

 

 

 

   

capable of supporting its weight and in a suitable area based on its dimensions and use.  

Make sure the product is not near any heat sources. 

 

 

Once the refrigerator cabinet is positioned in the intended area,

 

 

 

   

   

 

 

 

make sure it is level using the adjustable feet. 

 

Do  not  locate  the  REFRIGERATOR  CABINET  near 
heat sources or in areas with elevated temperatures 
since  this  could  lower  performance  and  increase 
equipment wear. Leave at least 50cm between the 
equipment and any upper surface (FIG.  3) 

Make  sure the  power  cable  is  not  under  the 
equipment. 

 

 

 

Summary of Contents for Superdry XSDC 601-01

Page 1: ...XSDC 601 01 Operation manual XSDC 601 01 ...

Page 2: ...ical Specifications 7 2 1 Description 7 2 2 Operating conditions 7 2 3 Function 7 2 4 Main Components 8 3 Ordinary Maintenance 9 3 1 Preliminary inspection operations 9 3 2 Internal and external cleaning of the refrigerator cabinet 9 3 3 Cleaning the condenser unit 9 4 Extraordinary Maintenance 9 5 Installation 10 5 1 Transport 10 5 2 Environmental specifications 10 5 3 Positioning 10 5 4 Space ne...

Page 3: ... Warranty and RMA Procedure 16 10 1 Warranty and liability 16 10 2 Full Warranty 16 10 3 Exchange warranty 16 10 4 Third year warranty 17 10 5 Guidelines for the RMA procedure of Totech Europe B V 17 11 Serial numbers 18 11 1 Cabinet serial numbers 18 12 CE Declaration 18 ...

Page 4: ... of and or have proven to possess the required expertise and know how have read and understood the safety information and precautions provided in this Operation Manual Furthermore the operator undertakes to regularly check its personnel s for a safety conscious mode of practice 1 3 Personnel Obligations All personnel assigned to operate the device undertake to comply with the relevant occupational...

Page 5: ...malfunction which might impede the device s safety 1 8 Protective devices Generally ensure all protective devices to be properly installed and functional before operating the device Protective devices may only be removed a After shutdown b As safeguarding against unintended restart For delivery of subcomponents the operator shall ensure the standard installation of protective devices 1 9 Electrica...

Page 6: ...for secure tightness After completion of the repair works check safety devices for functionality 1 12 Dehumidifier modification Any modification extension and or conversions to the device are subject to Totech EU s written consent Exclusively use original spare parts to ensure the device s proper and safe function and operation 1 13 Cabinet cleaning and disposal Ensure proper handling and disposal...

Page 7: ... not contain any free water water drops Ensure devices are not mounted in and or exposed to the intake of liquids e g filled tanks or sumps flooded areas etc Any operation in and or with potentially explosive ambience is not permissible 2 3 Function The device has been equipped with an easy to control logic display mounted in the front panel of the cabinet The respective module serves to control t...

Page 8: ...EAR RACK 11 UPPER HINGE 5 DIAGNOSTIC LED ONLY DEBATTER 12 CASING 6 CONVEYOR 13 LOWER HINGE 7 SWITCH 14 FOOT The shelves found inside the refrigerator cabinet have the following dimensions 530 x 500 mm The areas that come in contact with the product are made out of AISI 304 Stainless Steel or coated in non toxic plastic material The refrigerator units use refrigerant fluids permitted by current leg...

Page 9: ...oducts with chlorine caustic soda abrasive detergents muriatic acid vinegar bleach or other products that should scratch or abrade Also clean the exterior of the equipment with non aggressive detergent to prevent it from getting dirty 3 3 Cleaning the condenser unit All cleaning operations of the refrigerator monoblox or the incorporated condenser unit must be performed by qualified and authorized...

Page 10: ...itioning the equipment put on safety clothing and gloves for moving it since the metal parts could be sharp Position the product in a clean dry and well ventilated area The refrigerator is set for operation in environments where the temperature is between 18 C and 43 C Tropicalized Compressor Climate Class T The equipment should be located far from heat sources and in places with sufficient ventil...

Page 11: ...Do not obstruct the fan intake area Do not obstruct the upper part of the refrigerator or the air intakes when the refrigerator cabinet is in operation or under electrical power 6 2 Start up At the first startup make sure the refrigerator cabinet was transported only in a vertical position otherwise wait 8 hours from the time it was positioned before proceeding with start up Turn on the equipment ...

Page 12: ...he values to be set and for selecting the parameters 3 Key UP Used for increasing the value to be set for selecting parameters and for activating manual defrosting 4 Key U Used for visualising the temperatures taken by the cell and evaporator probes Pr1 and Pr2 5 Led OUT Indicates the compressor output status on on off off or inhibited flashing 6 Led DEF Indicates defrosting in progress on or drip...

Page 13: ...g the UP and DOWN keys it is possible to select another parameter if present and change it as described To return to select another group of parameters keep the UP or the DOWN key pressed for about 1 second after which the display will return to showing the code of the parameter group Release the pressed key and using the UP and DOWN keys it will be possible to select another group if present To e...

Page 14: ...art The refrigerator is already at the set temperature Set a lower temperature Motor unit failure Contact us at our service portal http service superdry totech com The compressor starts but the refrigerator doesn t cool and doesn t reach the set temperature Possible lack of refrigerant gas Contact us at our service portal http service superdry totech com The set temperature is too low Set the ther...

Page 15: ... of in the environment The doors must be removed before disposing of the equipment Temporary storage of special waste is permitted with the intention of disposal through final storage and or treatment The current laws regarding environmental protection in the country where used must be followed SAFETY FOR THE DISPOSAL OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE DIRECTIVE 2002 96 Do not dispo...

Page 16: ...ter purchase we provide warranty on all our new products unless agreed differently 10 2 Full Warranty Valid during the first year after purchase of the new product All drying cabinets cooling cabinets vacuum machines spare parts including dry units Full warranty The end user will receive the defective part replaced at no costs The transport costs are to be paid by the receiving party The defective...

Page 17: ...es to speed up the process Do not change rename and or delete any of the worksheets Please fill in the Company name Address Zip code City Country Tel nr Fax nr Contact person and Email Fill in ALL the yellow lines of the Complaint form starting with the first one When the complaint form is filled in correctly the overview sheet will be filled in automatically Use the Save as function in Excel to r...

Page 18: ...12 CE Declaration With this writing we Totech Europe BV De Linge 28 8253 PJ Dronten confirm that the cooling cabinet described corresponds with the fundamental safety and health demands of the following EC instructions EN55011 1998 A1 1999 A2 2002 EN61000 6 2 2001 2006 95 EG 2004 108 EG Totech Europe B V Gerhard Kurpiela ...

Reviews: