The model TOTALIFT TsMVC25 is already equipped with the adequate cable and plug
AC INPUT CONNECTION
The charger must be connected to the AC input using an adequate cable and plug, with
disconnect switch and fuses.
The AC input wires have to be connected to the TERMINAL BLOCKS FOR AC INPUT CABLE,
that are located over the main transformer (see picture on the next page).
Make sure to tighten the terminal block screws with the right torque, and pull each wire
separately in order to verify that they are mounted properly.
AC INPUT VOLTAGE SETTINGS
With reference to the following pictures, find the POWER TRANSFORMER TAPS and
the label with the list of the NOMINAL voltages available that are located on the left side
of the internal panel.
TsMVC 25
TsMVC 50
1
1x 120 VAC
1x 250 VAC
2
1x 115 VAC
1x 240 VAC
3
1x 110 VAC
1x 230 VAC
4
1x 105 VAC
//
Using an adequate AC-voltmeter, measure the value of the REAL AC input voltage
available at the mounting location of the charger.
Identify which of the NOMINAL voltage values is closest to the REAL measured value.
ATTENTION!
The proper setting of the power transformer taps is fundamental
for the correct operation of the Totalift TsMVC chargers.
If the real AC input voltage is different than the AC nominal voltage to which the charger is set,
the charging current of the charger may be significantly different than the nominal.