P . 10
■
Simultaneous operation
■
Simultaneous selective operation
←
to the Power supply
W B G R
W B G R
W B G R
W B G R
OPEN
STOP
CLOSE
←
to the Power supply
1
2
3
W B G R
OPEN
STOP
CLOSE
W B G R
OPEN
STOP
CLOSE
W B G R
OPEN
STOP
CLOSE
W B G R
W B G R W B G R
W B G R W B G R
W B G R W B G R
OPEN
STOP
CLOSE
ALL
Switch
Switch
1
Switch
2
Switch
3
W : White
B : Black
G : Green
R : Red
W : White
B : Black
G : Green
R : Red
Connecting the various switches
<3 Button Switch and
Infrared Remote Control
>
●
Follow the procedures illustrated in the figures below to connect the various switches to the main
unit.
The various function
setting switches
Setting Method of the various switches
●
Basic operating parameters or controls, including speed settings, can be set or controlled
using the switches on the Motor unit.
Speed Setting Switch
Address Setting Switch
P . 11
<FM Terminal>
Modular cord 1 m
to SW
to IR
to IR
Back side of Motor
Inlay Modular plate
Infra-red Receiver 01
(OPEN)
(STOP)
(COMMON)
(CLOSE)
Red
Black
White
Green
Modular cord 1 m
IR jack
FM RC
receiver 2.4G with IR terminal
FM Remote-control transmitter 2.4G (6ch)