7.1.12 LCD ERROR
Cause: PCB dead or LCD module has broken
LCD
Testing
Restore factory setting
Re-Download
Refer to (Updating program is failed)
Fail
No
Check LCD FPC and PCBA being connected
OK ?
(1) repair ACF LCD FPC
No
Check LCD module being
OK ?
Yes
(1) repair ACF LCD FPC
(2) Change LCD module
No
PCBA dead
Yes
Yes