Toshiba TOSVERT VF-AS1 Series Brochure & Specs Download Page 13

AB

Printed in Japan

05-07 (AB)8696

To users of our inverters : 

Our inverters are designed to control the speeds of three-phase induction motors for general industry.

For further information, please contact your nearest Toshiba Representative or International Operations-Producer Goods.

The information in this brochure is subject to change without notice. 

Overseas Sales & Marketing Department
Electrical Apparatus & Measurement Division

1-1,Shibaura 1-chome, Minato-ku,
Tokyo 105-8001,Japan
Tel.: +81(0)3-3457-4911  Fax.: +81(0)3-5444-9268

* Read the instruction manual before installing or operating the inverter unit and store it in a safe place for reference.
* When using our inverters for equipment such as nuclear power control, aviation and space flight control, traffic, and safety, and there 

is a risk that any failure or malfunction of the inverter could directly endanger human life or cause injury, please contact our 
headquarters, branch, or office printed on the front and back covers of this catalogue. Special precautions must be taken and such 
applications must be studied carefully.  

* When using our inverters for critical equipment, even though the inverters are manufactured under strict quality control always fit 

your equipment with safety devices to prevent serious accident or loss should the inverter fail (such as issuing an inverter failure  
signal). 

* Do not use our inverters for any load other than three-phase induction motors.
* None of Toshiba, its subsidiaries, affiliates or agents, shall be liable for any physical damages, including, without limitation, 

malfunction, anomaly, breakdown or any other problem that may occur to any apparatus in which the Toshiba inverter is incorporated 
or to any equipment that is used in combination with the Toshiba inverter. Nor shall Toshiba, its subsidiaries, affiliates or agents be 
liable for any compensatory damages resulting from such utilization, including compensation for special, indirect, incidental, 
consequential, punitive or exemplary damages, or for loss of profit, income or data, even if the user has been advised or apprised of 
the likelihood of the occurrence of such loss or damages.

Precautions

Summary of Contents for TOSVERT VF-AS1 Series

Page 1: ...Transistor Inverter High performance Inverter TOSVERT ...

Page 2: ...ance standard The factories manufacturing this product are ISO 14001 environmental management system registered factories ISO 9001 Certification Acquired ISO 14001 Certification Acquired For system devices that requires flexibility Feature My function High precision and high speed torque control with or without sensors Applications Process lines Printing machines Coilers uncoilers 3ø200V 3ø200V 3ø...

Page 3: ... in standard 400V class models 0 75 to 75kW EMI noise filter complies with the European EMC Directive built in standard 400V class models 90 to 500kW EMI noise filter complies with the European EMC Directive built in standard European EMC Directive IEC EN61800 3 1st Environment C2 or IEC EN61800 3 2nd Environment C3 For machinery that requires simple function POINT In the Quick mode pressing the E...

Page 4: ...nctions Ideal for Lifting Applications For system devices that requires flexibility With My function you can create programs containing up to 28 steps This achieves logic operations and internal data operations Parameters can also be set according to analog input and minimum peak hold of analog outputs For example Ex 1 Ex 2 Ex 3 Ex 4 Inverter is automatically switched to commercial operation witho...

Page 5: ...collector complimentary output 15 V Type VEC005Z 9 Point The photograph shows a screen currently in development 8 Wide Range of Applications Safety Environmental Compatibility The VF AS1 can be used at a rating up to an ambient temperature of 50 C and in environments up to 60 C at a derating current Ambient temperature 60 C 88 of materials used on the VF AS1 are recyclable which design more than m...

Page 6: ...ic torque boost auto tuning 1 2 Sensorless vector control 1 auto tuning 1 0 Disabled 1 Frequency setting by means of voltage 2 Frequency setting by means of current 3 Voltage current switching from external terminal 4 Frequency setting on operation panel and operation by means of terminals 5 Frequency setting and operation on operation panel 0 Terminal input enabled 1 Operation panel input enabled...

Page 7: ...en acceleration deceleration time torque limit and V f by set frequency Capable of restarting after a check of the main circuit elements in case the protective function is activated Max 10 times selectable arbitrarily Waiting time adjustment 0 to 10 sec The cooling fan will be stopped automatically to assure long life when unnecessary Possible to keep the motor running using its regenerative energ...

Page 8: ...14 138 158 190 210 206 280 114 138 158 190 210 206 206 280 220 249 283 283 386 403 525 220 249 283 283 386 403 529 605 A B C D E F H A B C D E F G I Figure G Figure H Figure I W H D W1 H1 External dimensions Figure A Figure B Figure C Figure D Figure E Figure F 200 V class 0 4 to 45 kW 400 V class 0 75 to 75 kW model W1 Installation dimension W 15 D 9 H H1 Installation dimension 2 R2 5 R 2 5 R 6 8...

Page 9: ...ø24 W D 7 2 R5 7 R 5 7 R 12 17 W D 7 H H2 H3 H4 W2 4 ø24 H1 Installation dimension W1 Installation dimension 2 R5 7 R 5 7 R 12 17 H H1 Installation dimension Braking Unit option 4 ø24 W1 Installation dimension W 75 D 7 2 R5 7 R 5 7 R 12 17 H H2 H3 H4 4 ø24 W D 7 75 W2 H1 Installation dimension Braking Unit option W1 Installation dimension 2 R5 7 R 5 7 R1 2 17 15 Figure J Figure J Figure K Figure K...

Page 10: ...Hz 90 500kW Three phase 380 440V 50Hz Three phase 380 480V 60Hz F R ST RES S1 S2 S3 RR S4 P24 PLC CC 1 PP RR S4 VI I I RX FM AM OUT1 OUT2 NO CCA 1 SU FLA FLB FLC Terminal Symbol Function Electrical Specifications Input output Lan current signal Choose low current contacts to avoid poor attaching Source input ON DC11V or more OFF Less than DC5V Input Input Input Input Input Input Input Input Output...

Page 11: ...ance between ground and the cable connecting the inverter and the motor Route 4 Leakage due to the capacitance of the cable connecting the motor and an inverter in another power distribution line Route 5 Leakage through the grounding line common to motors Route 6 Leakage to another line because of the capacitance of the ground Leakage current which passes through the above routes may cause the fol...

Page 12: ...his option when backing up only by the control power supply when the main circuit is shut off This is 24 VDC output common to both 200 and 400 V models Type CPS001Z This operation panel unit is for extension It is provided with an LED display RUN STOP key UP DOWN key monitor key and enter key Setup parameters for three inverters can be stored to this panel Type RKP002Z Connector cable for LED exte...

Page 13: ...covers of this catalogue Special precautions must be taken and such applications must be studied carefully When using our inverters for critical equipment even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail such as issuing an inverter failure signal Do not use our inverter...

Reviews: