SERIES OVERVIEW
Page 5
710-02887-00A
TMC7 Series
3.2
Dimensions & Weights
TMC7-007 ~ TMC7-030 (2.4kg)
98 (3.86)
165 (6.50)
82 (3.23)
C
23
(0.9)
23
(0.9)
Ready
Run
TOSHIBA INTERNATIONAL C ORPO RATIO N PTY
LTD - AUSTRALI A
SOFT STARTER
C1
R33 R34
C2
R43 R44 02 01 A2 A1 A3
Motor
Thermistor
Input
N.O.
N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
Start
Stop
RESET
Aux
Relay
Phase
Rotation
TRIP CODES
Ready
x 1. Power
Circuit
x 2. Excess
Start Time
x 3. Motor
Overload
x 4. Motor
Thermistor
x 5. Current
Imbalance
x 6. Supply
Frequency
x 7. Phase
Rotation
x 8. Comms
Failure
Motor FLC
(% TMC7 FLC)
Current Ramp
(%FLC/Ramp Time)
OFF
5s 15s
15
2s
5s
5s
2s
2s
15
70%
80%
60%
90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%
300%
250%
Motor Trip
Class
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s 10s 12s
14s
16s
20s
TMC7
SE RIES
Soft Stop
(Seconds)
No
Soft Stop
2s
4s
6s
8s 10s 12s
14s
16s
20s
TMC7-037 ~ TMC7-055 (4.3kg)
145 (5.71)
193 (7.60)
37
(1.46)
37
(1.46)
124 (4.88)
Ready
Run
TOSHIBA INTERNATIONAL COR PORATION PTY
LTD - AUSTRALIA
SOFT STARTER
C1
R33 R34
C2
R43 R44 02 01 A2 A1 A3
Motor
Thermistor
Input
N.O.
N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
Start
Stop
RESET
Aux
Relay
Phase
Rotation
TRIP CODES
Ready
x 1. Power
Circuit
x 2. Excess
Start Time
x 3. Motor
Overload
x 4. Motor
Thermistor
x 5. Current
Imbalance
x 6. Supply
Frequency
x 7. Phase
Rotation
x 8. Comms
Failure
Motor FLC
(% TMC7 FLC)
Current Ramp
(%FLC/Ramp Time)
OFF
5s
15s
15
2s
5s
5s
2s
2s
15
70%
80%
60%
90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%
300%
250%
Motor Trip
Class
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s 10s 12s
14s
16s
20s
TMC7
SERIES
Soft Stop
(Seconds)
No
Soft Stop
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC7-075 ~ TMC7-110 (6.8kg)
202 (7.95)
214 (8.43)
160 (6.30)
51
(2.0)
51
(2.0)
Ready
Run
TOSHIB A INTERNATIONAL CORPORATION PTY
LTD - AUSTRALIA
SOFT STARTER
C1
R33 R34
C2
R43R44 02 01 A2 A1 A3
Motor
Thermistor
Input
N.O.
N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
Start
Stop
RESET
Aux
Relay
Phase
Rotation
TRIP CODES
Ready
x 1. Power
Circuit
x 2. Excess
Start Time
x 3. Motor
Overload
x 4. Motor
Thermistor
x 5. Current
Imbalance
x 6. Supply
Frequency
x 7. Phase
Rotation
x 8. Comms
Failure
Motor FLC
(% TMC7 FLC)
Current Ramp
(%FLC/Ramp Time)
OFF
5s 15s
15
2s
5s
5s
2s
2s
15
70%
80%
60%
90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%
300%
250%
Motor Trip
Class
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC
7
SER IES
Soft Stop
(Seconds)
No
Soft Stop
2s
4s
6s
8s 10s 12s
14s
16s
20s