3.10 Async Test
3 Tests and Diagnostics
3.10 Async
Test
To execute the Async Test, select
7
from the DIAGNOSTIC TEST MENU, press
Enter
and
follow the directions displayed on the screen. The Async test contains six subtests that test
the asynchronous communication functions. Move the highlight bar to the subtest you want
to execute and press
Enter.
Subtests require the following data format:
Method: Asynchronous
Speed:
9600BPS (subtests 01 to 04)
38400BPS (subtests 06, 07)
Data:
8 bits and one parity bit (EVEN)
Data pattern: 20h to 7Eh
The following message will appear at the bottom of the screen when the subtest 01, 02 or 03
are selected.
Channel#1 = XXXXh
Channel#2 = XXXXh
Channel#3 = XXXXh
Select the Channel number (1/2/3)
The serial I/O port address is specified by the XXXXh number. Select the serial port channel
number and press
Enter
to start the subtest.
Subtest 01
Wrap around (board)
NOTE
: To execute this subtest, a RS-232C wraparound connector (34M741621G01)
must be connected to the RS-232C port in the Advanced Port Replicator III. The
RS-232C wraparound connector wiring diagram is described in Appendix F.
This subtest checks the data send/receive function through the wraparound
connector.
Subtest 02
Point to point (send)
NOTE
: To execute this subtest, two machines must be connected with an RS-232C direct
cable. One machine should be set as “send”(subtest 02) and the other set as
“receive” (subtest 03). The wiring diagram for the RS-232C direct cable is
described in Appendix F.
This subtest sends 20h through 7Eh data to the receive side, then receives the
sent data and compares it to the original data.
TECRA M2V Maintenance Manual (960-476)
3-25
Summary of Contents for Tecra M2V
Page 10: ...x TECRA M2V Maintenance Manual 960 476 ...
Page 11: ...Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii TECRA M2V Maintenance Manual 960 476 ...
Page 50: ...1 Hardware Overview 1 13 Batteries 1 36 TECRA M2V Maintenance Manual 960 476 ...
Page 51: ...Chapter 2 Troubleshooting Procedures ...
Page 52: ...2 Troubleshooting Procedures 2 ii TECRA M2V Maintenance Manual 960 476 ...
Page 56: ...2 Troubleshooting Procedures 2 vi TECRA M2V Maintenance Manual 960 476 ...
Page 111: ...Chapter 3 Tests and Diagnostics ...
Page 112: ...3 Tests and Diagnostics 3 ii TECRA M2V Maintenance Manual 960 476 ...
Page 195: ...Chapter 4 Replacement Procedures ...
Page 196: ...4 Replacement Procedures 4 ii TECRA M2V Maintenance Manual 960 476 ...
Page 200: ...4 Replacement Procedures 4 vi TECRA M2V Maintenance Manual 960 476 ...
Page 274: ...4 Replacement Procedures 4 23 LCD unit FL inverter 4 74 TECRA M2V Maintenance Manual 960 476 ...
Page 296: ...4 Replacement Procedure 4 26 Fluorescent Lamp 4 96 TECRA M2V Maintenance Manual 960 476 ...
Page 297: ...Appendices ...
Page 298: ...Appendices App ii TECRA M2V Maintenance Manual 960 476 ...
Page 304: ...Appendices App viii TECRA M2V Maintenance Manual 960 476 ...
Page 310: ...Appendices Appendix A Handling the LCD Module A 6 TECRA M2 Maintenance Manual 960 468 ...
Page 356: ...Appendices Appendix E Key Layout E 2 TECRA M2V Maintenance Manual 960 476 ...
Page 360: ...Appendices Appendix G BIOS rewrite procedures G 2 TECRA M2V Maintenance Manual 960 476 ...
Page 362: ...Appendices Appendix H EC KBC rewrite procedures H 2 TECRA M2V Maintenance Manual 960 476 ...
Page 364: ...Appendices Appendix I Reliability I 2 TECRA M2V Maintenance Manual 960 476 ...