Click
“Ready”
button.
Click
“Initial”
button.
Click
“AF”
button. AF Calibration Chart is appeared.
Click
“Move Far”
and
“Move Near”
button are clicked, and focused a picture.
Click
“Calibration”
button.
A calibration number goes into the box of “WIDE”.
2 times of calibrations are similarly performed after this.
“Go Middle”
- “AF” - “Move Far” or “Move Near”. Focus a picture. “Calibration”
“Go Tele”
- “AF” - ““Move Far” or “Move Near”. Focus a picture. “Calibration”
Press
[Return]
button. Escape from AF Communication Mode.
Press the buttons,
[Return]
and
[Up]
simultaneously. Service Status screen is displayed. (See page 7-3)
Temp-1 (T1) and Temp-2 (T2) are read, and setting temperature is calculated from the following formulas.
T=T1+0.55(T2-T1) TW95 Series
T=T1+0.45(T2-T1) TW100 Series
T is inputted into a temperature input box.
Return AF Communication Mode.
Click
“Temperature”
button.
A projector is restarted (AC off/on).
Execute
[Easy Setup]
, and check the AF performance.
Summary of Contents for TDP-TW100B
Page 1: ......
Page 2: ...I ...
Page 4: ...1 1 Chapter 1 Specifications Chapter 1 ...
Page 12: ...Chapter 2 2 3 Parts Replacement ...
Page 13: ...Chapter 2 2 4 ...
Page 14: ...Chapter 2 2 5 ...
Page 15: ...Chapter 2 2 6 ...
Page 16: ...Chapter 2 2 7 ...
Page 17: ...Chapter 2 2 8 ...
Page 18: ...Chapter 2 2 9 ...
Page 30: ...5 1 Chapter 5 Wiring Diagram Chapter 5 ...
Page 31: ...Chapter 5 5 2 Block Diagram 1 2 Block Diagram ...
Page 32: ...Chapter 5 5 3 Block Diagram 2 2 ...
Page 53: ...Chapter 6 6 21 ...
Page 54: ...Chapter 6 6 22 ...
Page 55: ...Chapter 6 6 23 APS M602 ETXTS602MDA MDE Troubleshooting Faults ...
Page 83: ...9 1 Chapter 9 Spare Parts List Exploded View Chapter 9 ...
Page 84: ...Chapter 9 9 2 Exploded View Optical Engin ...
Page 85: ...Chapter 9 9 3 Other Parts ...
Page 86: ...Chapter 9 9 4 ...
Page 87: ...Chapter 9 9 5 ...
Page 88: ...Chapter 9 9 6 ...
Page 89: ...Chapter 9 9 7 ...
Page 90: ......