background image

– 1 –

EN-1

EN-2

Contents

1

Precautions for Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2

Designated Indoor Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

3

Packing List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

4

Part Names  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

5

Dimension  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

6

Location for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

7

Space for Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

8

Installation of 3DW Diffusor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

9

Installation for Front Panel Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

10

Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

11

Setting Parameter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

12

Trial Operation and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

13

Fan Characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1

Precautions for Safety

The manufacturer shall not assume any liability for the damage caused by not observing the 
description of this manual.

The following contents are very important to prevent any harm to users and others and damage to property. Please fully 
understand the contents (signs, graphic symbols) before reading the text and then follow the instructions.

Before installation, please read the installation manual carefully.

Thank you for purchasing TOSHIBA 3DW Diffusor.

This installation manual describes the installation method for the 3DW Diffusor.

Please install the indoor unit according to the attached installation manual for the indoor unit.

When the installation is completed, please be sure to confirm according to the content of “12. Trial Operation and 
Inspection
”, fully explain the contents described in the owner’s manual to the customer, and hand over the owner’s 
manual and the installation manual to the customer for safekeeping.

Mark

Description

WARNING

Indicate situations where incorrect operation may cause death or serious injury to the 
user 

(*1)

.

CAUTION

Indicate situations where incorrect operation may cause minor injury 

(*2)

 to the user or 

damage to objects 

(*3)

.

PROHIBITION

Indicate prohibited items or actions to be avoided. The detailed items or actions will be 
illustrated by graphics or words inside or next to this symbol.

*1:  Serious injuries refer to those that require hospitalization or long-term follow-up treatment due to physical sequel caused 

by blindness, injury, scald (in both high and low temperature), electric shock, fracture, poisoning, etc.

*2:  Minor injuries refer to those injuries, scalds, electrocutions, etc. that do not require hospitalization or long-term follow-up 

treatment.

*3:  Object damage refers to those extensive loss involving houses, property, poultry, pets, etc.

WARNING

Before installation, please read the installation procedure carefully and follow the instructions. Failure to follow 
instructions may result in drop, noise, vibration, water leakage and other problems. 

Only a qualified installer or qualified service person is allowed to carry out the installation work. Improper installation may 
result in water leakage, electric shock, fire and other problems.  

Before the installation, maintenance, repair or removal work, please set the circuit breaker to the OFF position, otherwise 
there is a risk of electric shock.  

During the installation, maintenance, repair or removal work, please place a sign of “in operation” near the circuit breaker. 
There is a danger of electric shock if the circuit breaker is turned on by mistake.  

Only a qualified installer or qualified service person is allowed to carry out the work at heights on the bracket over 50 cm or 
remove the 3DW Diffusor. 

Please wear safety clothing and protective gloves during the installation, maintenance or disassembly work. 

When working at heights, please use a ladder conforming to ISO 14122 standard and follow the instructions in its manual. 
In addition, please wear industrial safety helmet as protective equipment during the work.  

Before cleaning the panel and other parts, please set the circuit breaker to the OFF position, and place a sign of 
“in operation” near the circuit breaker during the work.  

During the operation, please confirm whether the air conditioner is in a stable state. If the product is partially damaged, 
please contact the sales store.  

Only a qualified installer or qualified service person is allowed to move the 3DW Diffusor. Unlicensed operation is extremely 
dangerous and may cause fire, electric shock, injury, water leakage, noise, vibration and other problems. 

Please be sure to use it together with the indoor unit designated by our company. Use non-designated products may cause 
fire, electric shock, water leakage and other problems.

2

Designated Indoor Unit

Please use the 3DW Diffusor it together with the indoor units listed in the table below.

Please do not connect the 3DW Diffusor with model number MMD-UP0031* indoor unit, otherwise dewing on the product 
maybe caused. 

Model of 3DW Diffusor

Designated indoor unit

TCB-TDL0141SDY-E

MMD-UP0051SPHY-E, MMD-UP0071SPHY-E, 
MMD-UP0091SPHY-E, MMD-UP0121SPHY-E

TCB-TDL0181SDY-E

MMD-UP0151SPHY-E, MMD-UP0181SPHY-E

TCB-TDL0271SDY-E

MMD-UP0241SPHY-E, MMD-UP0271SPHY-E

TCB-TDL0141SDY-TR

MMD-UP0051SPHY-TR, MMD-UP0071SPHY-TR, 
MMD-UP0091SPHY-TR, MMD-UP0121SPHY-TR

TCB-TDL0181SDY-TR

MMD-UP0151SPHY-TR, MMD-UP0181SPHY-TR

TCB-TDL0271SDY-TR

MMD-UP0241SPHY-TR, MMD-UP0271SPHY-TR

Summary of Contents for TCB-TDL0141SDY-E

Page 1: ...s Ελληνικα Svenska Suomi Norsk Dansk Română Български Eesti Latviski Slovenčina Slovenščina AIR CONDITIONER ACCESSORY Installation Manual 3DW Diffusor Model name TCB TDL0141SDY E TCB TDL0181SDY E TCB TDL0271SDY E TCB TDL0141SDY TR TCB TDL0181SDY TR TCB TDL0271SDY TR For commercial use Ticari kullanım için ...

Page 2: ...ctions may result in drop noise vibration water leakage and other problems Only a qualified installer or qualified service person is allowed to carry out the installation work Improper installation may result in water leakage electric shock fire and other problems Before the installation maintenance repair or removal work please set the circuit breaker to the OFF position otherwise there is a risk...

Page 3: ...ulation sponge Inside heat insulation for mounting frame 190 33 6 1 3 Fixing screw for mounting frame M4x8 16 9 Wire clip 1 10 Binding belt 2 4 Fixing screw for front panel assembly M4x25 6 11 Owner s manual 1 12 Installation manual this manual 1 4 Part Names 5 Dimension Unit mm Horizontal louver swing up and down Vertical louver swing left and right Panel 34 5 11 80 5 7 5 21 6 61 180 94 42 Distan...

Page 4: ...door 3 Kitchen 4 A place where the 3DW Diffusor is exposed to the outdoor air directly In the above places please paste heat insulation materials such as sponges on the panel and the horizontal louver of 3DW Diffusor that are exposed to high humidity air Reference Test conditions for condensation Indoor Dry ball temperature 27 C Wet ball temperature 24 C Air volume Low Running time 4 hours 7 Space...

Page 5: ... frame Only 12 places on TCB TDL0141SDY C need to be fixed meaning there will be 4 fixing screws for mounting frame 3 left 3 Fixing screw for mounting frame 2 Mounting frame Indoor unit Sticking sponge on mounting frame Please stick 2 pieces of sponge 5 and 2 pieces of sponge 6 that are attached with the machine to the fixed screws for mounting frame 3 Please stick the attached sponge 7 onto the a...

Page 6: ...g and fix the mounting frame with screws Please install the indoor unit and connect the pipelines Perform the heat insulation treatment on the refrigerant connecting pipe and drainage pipe For details refer to the installation manual of the indoor unit Please make the drill on the wall according to Drilling on the wall Please refer to the figure below to install the wooden frame locally purchased ...

Page 7: ...cting wire of the front panel assembly 1 to the wall opening and then push the front panel assembly 1 into the opening Temporarily fix two screws at the central part of the panel assembly 1 with the complimentary fixing screws for panel assembly M4x25 4 Similarly after temporarily fixing the remaining 4 screws tighten all the screws 6 in total Pay attention to the tightening sequence of the screws...

Page 8: ... drainpipe Side cover of PCB board Plug of PCB board Plug the connector of the wire into the PCB board socket CN510 white To protect the PCB board from the external pressure fix the connecting wire on a wire clip on the back of the side cover of the PCB board about 100 mm away from the plug with the binding belt 10 Close the side cover of the PCB board and fix it with 2 screws Tidy wires Tidy the ...

Page 9: ...l static pressure Please refer to the installation manual of indoor unit for the setting method of external static pressure The pressure loss characteristics of 3DW Diffusor will affect the external static pressure Please refer to the attached fan characteristics for details To avoid deviation from the operating range please adjust the air volume by adjusting the air doors set at the suction and a...

Page 10: ...door unit before the trial operation of the 3DW Diffusor For details refer to the installation manual of the indoor unit Please control the operation of the horizontal louver and vertical louver by the remote controller and confirm that the movement and sound are normal Refer to the manual of the remote controller for operation The clearance on the right side of the horizontal louver must be even ...

Page 11: ...35 200 300 400 500 600 700 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa Low 10 Pa High 20 Pa High 10 Pa 0 5 10 15 20 25 30 35 40 400 500 600 700 800 900 1000 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa Low 10 Pa High 20 Pa High 10 Pa 0 5 10 15 20 25 30 35 40 400 500 600 700 800 900 1000 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa ...

Page 12: ...D0X7203601 00 ...