8. MCD
+
Op-Amp Mode
In MCD + Op-Amp mode, the speed control part realizes the closed loop by using PI control.
•
The VSP is used to determine the target speed.
•
The LA voltage is used as a feedback signal to represent current speed.
•
The Dif-in is used to adjust output duty to control motor speed.
•
PWM-in should be connected to GND.
Figure 8-1 MCD + Op-Amp Mode