2-37
If these connectors are not connected, connect them and refer back to Procedures 1 and 2. If the
problem still exists, refer to Procedure 4.
Procedure 4
Replacement Check
In the T2000, the FL inverter, LCD module, and system board are connected with the display
circuits. Any of these units may be damaged. Refer to Part 4 for instructions on how to disas-
semble the system unit and then perform the following checks.
Check 1
Replace the FL inverter with a new one and recheck the display. If the problem still
exists, refer to Check 2.
Check 2
Replace the LCD module with a new one and recheck the display. If the problem
still exists, refer to Check 3.
Check 3
The system board may be damaged. Replace the system board with a new one and
recheck the display. If the problem still exists, refer to Check 4.
Check 4
The LED board may be damaged. Replace the LED board with a new one.
Summary of Contents for T-Series T2000
Page 1: ...1 1 Part 1 Hardware Overview ...
Page 2: ...1 2 This page intentionally left blank ...
Page 4: ...1 4 This page intentionally left blank ...
Page 15: ...2 1 Part 2 Problem Isolation Procedures ...
Page 16: ...2 2 This page intentionally left blank ...
Page 18: ...2 4 This page intentionally left blank ...
Page 52: ...2 38 This page intentionally left blank ...
Page 53: ...3 1 Part 3 Tests and Diagnostics ...
Page 54: ...3 2 This page intentionally left blank ...
Page 113: ...4 1 Part 4 Replacement Procedures ...
Page 114: ...4 2 This page intentionally left blank ...
Page 141: ...App 1 Appendices ...
Page 142: ...App 2 This page intentionally left blank ...
Page 146: ...App 6 Figure A 1 System board FA2SYx ICs Back I M M N S W V P R R U ...
Page 151: ...App 11 Figure A 3 System board FA2SYx connectors Back PJ1 A ...
Page 161: ...App 21 Appendix C ASCII Character Codes Table C 1 ASCII character codes ...
Page 174: ...T2000 Notes ...