2-23
Check 3
Clean the read/write head using the 3.5-inch FDD cleaning kit. If the problem still
exists, refer to Procedure 3.
Procedure 3
Test Program Check
The FDD test program is stored on the T2000 Diagnostics Disk. After loading Toshiba MS-DOS,
run the Diagnostic Program (TESTCE2). Refer to Part 3 for detailed instructions about the FDD
test.
Insert a formatted floppy disk and then start the FDD test. The error code and status are described
in Table 2-3.
If an error occurs, refer to Check 1.
Table 2-3 FDD error code and status
Check 1
If the
Write protected
message appears, remove the write protect tab on the
Code
Status
01h
Bad command
02h
Address mark not found
03h
Write protected
04h
Record not found
06h
Media removed on dual attach card
08h
DMA overrun error
09h
DMA boundary error
10h
CRC error
20h
FDC error
40h
Seek error
60h
FDD not drive
80h
Time out error (Not ready)
EEh
Write buffer error
Summary of Contents for T-Series T2000
Page 1: ...1 1 Part 1 Hardware Overview ...
Page 2: ...1 2 This page intentionally left blank ...
Page 4: ...1 4 This page intentionally left blank ...
Page 15: ...2 1 Part 2 Problem Isolation Procedures ...
Page 16: ...2 2 This page intentionally left blank ...
Page 18: ...2 4 This page intentionally left blank ...
Page 52: ...2 38 This page intentionally left blank ...
Page 53: ...3 1 Part 3 Tests and Diagnostics ...
Page 54: ...3 2 This page intentionally left blank ...
Page 113: ...4 1 Part 4 Replacement Procedures ...
Page 114: ...4 2 This page intentionally left blank ...
Page 141: ...App 1 Appendices ...
Page 142: ...App 2 This page intentionally left blank ...
Page 146: ...App 6 Figure A 1 System board FA2SYx ICs Back I M M N S W V P R R U ...
Page 151: ...App 11 Figure A 3 System board FA2SYx connectors Back PJ1 A ...
Page 161: ...App 21 Appendix C ASCII Character Codes Table C 1 ASCII character codes ...
Page 174: ...T2000 Notes ...