Strata CIX Media Application Server Installation 07/06
1
Hardware
The MAS is a multi-function server that connects through an Network Switch to the CIX IP Local
Area Network (LAN) connection on the CIX processor card.
The MAS operating system is Windows
®
XP. The system is shipped with Service Pack 2 (SP2)
installed.
Input Power
The MAS is supplied with a standard 15 Amp power cord with a standard three-prong 120 VAC that
plugs into an AC power outlet. The MAS requires:
•
A dedicated, properly grounded circuit
Note
No additional grounding is required provided the AC outlet is properly grounded.
•
An input power source of 120 VAC, 50 or 60 Hz, 5.67 amps (max)
Power Failure Backup
Customer-supplied commercially available UPS systems should be used for power failure backup.
Grounding
The MAS does not need any additional grounding provided the AC outlet is properly grounded.
Connection
The MAS connects to the CIX using a single IP connection through a Network Switch. All of the
feature communications and Voice Mail speech paths are carried by this one connection.
The monitor, keyboard and mouse are customer-supplied options. The MAS can be accessed via
the network by using the Windows® XP Remote Desktop feature.
Figure 1
MAS Connection Block Diagram
CIX
MAS
Network Switch
*Monitor
*Key Board
*Mouse
LAN
*Optional