NOTE

Auto Changeover

• When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point 

temperature.

• If the Auto mode is uncomfortable, you can select the desired conditions manually.

Cooling

• If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.

Heating

• If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
• After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely 

low speed.

 

During defrost operation, the fan stops so that cool air is not discharged. (“

” Pre-heat is displayed.)

When restarting the operation after stop

When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes this is to 
protect the compressor.

„

8 °C Operation (For object pre-heating)

 

 

(SDI series 4 and DI series 4 (RAV-SP***4AT / RAV-SM***4AT) only)

The air conditioner can control the heating temperature to about 8 °C in the heating mode.

The 8 °C heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings 
according to the installation manual of the indoor unit.

 

Start

1

Set the displayed temperature to 18 °C in the heating mode by pushing TEMP. 

 button.

2

Set the displayed temperature to 8 °C by pushing TEMP. 

 button for at least four seconds.

Stop

1

Set the displayed temperature to 18 °C by pushing TEMP. 

 button.

• The air conditioner returns to the normal Heat mode. Select a desired temperature and operation mode.

NOTE

• The discharged air temperature is lower than that in the normal heating operation.
• The room temperature may not be heated evenly depending on the remote controller installation location.
• The room temperature may not reach 8 °C depending on the room size or the installation conditions.
• Setting for fan speed is available during the 8 °C heating operation.

The 8 °C heating operation is cancelled in the following cases.
•When operation is stopped with 

 button

•When another operation mode is selected with 

 button

•When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote controller 

or the central control remote controller.

• When this operation mode is used, observe proper operating hours and periodic maintenance by service staff is 

recommended.

5

Timer Operation

• Three timer modes are available: (Setting of up to 168 hours is enabled.)

Set

1

Push  

button.

The timer mode changes with every push of the button.

 and timer display flashes.

2

Push 

 to select “set time”.

• With every push of 

 button, the set time increases 

by 0.5 hr (30 minutes).

 

When setting a time more than 24 hours for timer 
operation, timer can be set in increments of 1 hr. 

 

The maximum set time is 168 hr (7 days).

 

The remote control displays the set time with time 
(between 0.5 and 23.5 hours) (*

1

) or number of days 

and time (24 hours or more) (*

2

) as shown below.

• With every push of 

 button, the set time decreases 

by 0.5 hr (30 minutes) (0.5 - 23.5 hours) or 1 hr (24 - 
168 hours).

Example of remote control display

• 23.5 hours (*

1

)

• 34 hours (*

2

)

3

Push  

button.

 icon disappears and time display goes on, 

and 

 or 

 icon flashes.

 

(When On timer is activated, time and On timer 

 are icons and other icons disappear.)

4

Cancel timer operation

Push  

button.

Timer icon disappears.

NOTE

• When the operation stops after the timer reached the preset 

time, the Repeat Off timer resumes the operation by 
pushing 

 button and stops the operation after the 

time of the timer has reached the set time.

• When 

 is pushed while the Off timer function of the 

air conditioner is active, the indication of the timer function 
disappears and then appears again after about 5 
seconds

.

 

This is due to normal processing of the remote controller.

Off timer

: The unit stops when the set time is reached.

Repeat Off timer

: The unit stops daily when the set time is reached.

On timer

: The unit starts when the set time is reached.

3


4

shows 1 day (24 hours).

shows 10 hours. (Total 34 hours)

(Off timer)

(On timer)

(Repeat Off timer)

No display

Off

Off

On

Number of days Time

13-EN

14-EN

+00EH99937799_01EN.book  Page 7  Thursday, March 31, 2011  10:00 PM

Summary of Contents for RAV-SM404MUT-E

Page 1: ...s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Compact 4 way Type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E 00EH99937799_01EN book Page 1 Thursday March 31 2011 10 00 PM ...

Page 2: ...tallation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an indi...

Page 3: ...l work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker ...

Page 4: ... ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock or other trouble Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer or a qualified service person Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To d...

Page 5: ... notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air f...

Page 6: ...to save energy SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 20 11 14 13 12 18 8 7 Auto High Med Low 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used...

Page 7: ... on the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Prepara...

Page 8: ...ailable during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe prope...

Page 9: ...peration The louver direction changes for every push of the button In HEAT operation Direct the louver adjustment plate of up down wind direction downward If directing at horizontally hot air may not come to the foot In COOL DRY operation Direct the louver adjustment plate of up down wind direction horizontally If directing it downward the dew may form on the surface of the air discharge port and ...

Page 10: ...de The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled To cancel the power saving mode push button again disappears To configure the power saving mode sett...

Page 11: ...in power saving mode 8 Self Clean Mode This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self clean time varies with the cooling dry Auto cooling operation time as follows is displayed on the remote controller during self clean operation To stop self clean forcibly push button twice ...

Page 12: ...mmended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general...

Page 13: ...xpands and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote control...

Page 14: ... proper performance operate the air conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess o...

Page 15: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Cond...

Page 16: ...ORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99937799_01EN book Page 33 Thursday March 31 2011 10 00 PM ...

Reviews: