background image

– 2 –

Compact 4-way Type

Owner’s Manual

EN

Compact 4-way Type

Owner’s Manual

„

Warning indications on the air conditioner unit

Warning indication

Description

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote electric power supplies before servicing.

WARNING

Moving parts. 
Do not operate unit with grille removed. 
Stop the unit before the servicing.

CAUTION

High temperature parts. 
You might get burned when removing this panel.

CAUTION

Do not touch the aluminum fins of the unit. 
Doing so may result in injury.

CAUTION

BURST HAZARD

Open the service valves before the operation, otherwise there might be the 
burst.

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote 
electric power supplies 
before servicing.

WARNING

Moving parts.
Do not operate unit with grille 
removed.
Stop the unit before the servicing.

CAUTION

High temperature parts.
You might get burned 
when removing this panel.

CAUTION

Do not touch the aluminum 
fins of the unit.
Doing so may result in injury.

CAUTION

BURST HAZARD

Open the service valves before 
the operation, otherwise there 
might be the burst.

1

Precautions for Safety

The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.

WARNING

General

• Carefully read Owner’s Manual before starting the air conditioner. There are many important things to keep in mind 

for daily operation.

• Ask for installation to be performed by the dealer or a professional. Only a qualified installer (*1) is able to install an 

air conditioner. If a non-qualified person installs an air conditioner, it may result in problems such as fire, electric 
shock, injury, water leakage, noise and vibration. 

• Do not use any refrigerant different from the one specified for complement or replacement. Otherwise, abnormally 

high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or 
an injury to your body.

• Places where the operation sound of the outdoor unit may cause a disturbance. (Especially at the boundary line with 

a neighbour, install the air conditioner while considering the noise.)

Transportation and storage

• To transport the air conditioner, wear shoes with protective toe caps, protective gloves, and other protective clothing.
• To transport the air conditioner, do not take hold of the bands around the packing carton. You may injure yourself if 

the bands should break.

• Before stacking the packing cartons for storage or transportation, heed the precautions written on the packing 

cartons. Failure to heed the precautions may cause the stack to collapse.

• The air conditioner must be transported in stable condition. If any part of the product broken, contact your dealer.
• When the air conditioner must be transported by hand, carry it by two or more people.

Installation

• Only a qualified installer(*1) or qualified service person(*1) is allowed to carry out the electrical work of the air 

conditioner. Under no circumstances must this work be done by an unqualified individual since failure to carry out the 
work properly may result in electric shocks and / or electrical leaks.

• After the installation work has been completed, have the installer explain about the circuit breaker positions. In the 

event that trouble has occurred in the air conditioner, set the circuit breaker to the OFF position, and contact a service 
person.

• If the unit is installed in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit 

concentration even if it leaks. Consult the dealer from whom you purchased the air conditioner when you implement 
the measures. Accumulation of highly concentrated refrigerant may cause an oxygen deficiency accident.

• Do not install the air conditioner in a location that may be subject to a risk of expire to a combustible gas. If a 

combustible gas leaks and becomes concentrated around the unit, a fire may occur.

• Use the company-specified products for the separately purchased parts. Use of non-specified products may result in 

fire, electric shock, water leakage or other trouble. Have the installation performed by a professional.

• Confirm that earthing is performed correctly. 

Operation

• Before opening the intake grille of the indoor unit or service panel of the outdoor unit, set the circuit breaker to the 

OFF position. Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with 
the interior parts. Only a qualified installer(*1) or qualified service person(*1) is allowed to remove the intake grille of 
the indoor unit or service panel of the outdoor unit and do the work required.

• Inside the air conditioner are high-voltage areas and rotating parts. Due to the danger of electric shocks or of your 

fingers or physical objects becoming trapped in the rotating parts, do not remove service panel of the outdoor unit. 
When work involving the removal of these parts is required, contact a qualified installer or a qualified service person.

• Do not move or repair any unit by yourself. Since there is high voltage inside the unit, you may get electric shock 

when removing the cover and main unit.

• Use of a stand more than 50 cm high to clean the filter of the indoor unit or to carry out other such jobs constitutes 

working at heights. Due to the danger of falling off the stand and injuring yourself while working at heights, this kind 
of work should not be done by unqualified individuals. When this kind of work must be carried out, do not do it yourself 
but ask a qualified installer or a qualified service person to do it for you.

• Do not touch the aluminum fin of the outdoor unit. You may injure yourself if you do so. If the fin must be touched, do 

not touch it yourself but contact a qualified installer or a qualified service person.

• Do not climb onto or place objects on top of the outdoor unit. You may fall or the objects may fall off of the outdoor 

unit and result in injury.

3-EN

4-EN

+00EH99937799_01EN.book  Page 2  Thursday, March 31, 2011  10:00 PM

Summary of Contents for RAV-SM404MUT-E

Page 1: ...s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Compact 4 way Type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E 00EH99937799_01EN book Page 1 Thursday March 31 2011 10 00 PM ...

Page 2: ...tallation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an indi...

Page 3: ...l work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker ...

Page 4: ... ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock or other trouble Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer or a qualified service person Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To d...

Page 5: ... notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air f...

Page 6: ...to save energy SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 20 11 14 13 12 18 8 7 Auto High Med Low 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used...

Page 7: ... on the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Prepara...

Page 8: ...ailable during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe prope...

Page 9: ...peration The louver direction changes for every push of the button In HEAT operation Direct the louver adjustment plate of up down wind direction downward If directing at horizontally hot air may not come to the foot In COOL DRY operation Direct the louver adjustment plate of up down wind direction horizontally If directing it downward the dew may form on the surface of the air discharge port and ...

Page 10: ...de The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled To cancel the power saving mode push button again disappears To configure the power saving mode sett...

Page 11: ...in power saving mode 8 Self Clean Mode This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self clean time varies with the cooling dry Auto cooling operation time as follows is displayed on the remote controller during self clean operation To stop self clean forcibly push button twice ...

Page 12: ...mmended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general...

Page 13: ...xpands and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote control...

Page 14: ... proper performance operate the air conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess o...

Page 15: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Cond...

Page 16: ...ORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99937799_01EN book Page 33 Thursday March 31 2011 10 00 PM ...