Selectin
g th
e
mod
e
l name and serial
No.
2
Lit
e
-V
is
ion
plus Remot
e
C
ontro
ll
er
Installation
Manual
Push the [
∧
] /
[
∨
] button t
o
select
“
1
. Manual
mod
e
l n
a
me i
nput” on
the
“
O
utdoor model
name
” screen,
th
e
n
push
the
“
Set”
[
F2] button.
Æ
Se
le
c
t “1.
Man
ual seria
l
No.
in
put” to e
n
ter the
ser
ial num
ber
of t
he ou
tdoor
un
it
.
Æ
Se
le
c
t “1.
Man
ual m
odel na
me inp
ut”
to en
ter
th
e mo
del nam
e o
f the ind
oor
unit.
Æ
Se
le
c
t “1.
Man
ual seria
l
No.
in
put” to e
n
ter the
ser
ial num
ber
of t
he indo
or
unit.
3
Enter the model
name
of
the outdo
or unit.
Æ
Se
e
pag
e 13
abou
t how to e
n
ter
the
mod
e
l
na
me
and ser
ial num
ber
.
4
Select “Remot
e
contr
o
ller” for the display
mode of mo
del name
o
r seri
a
l number
to
displ
a
y
the manual
ly
entered model
name
or
se
rial n
u
m
b
er.
(S
ee
page 13
.)
1
Push the [
∧
] /
[
∨
] button t
o
select
“
2
.
Model name selection” on
the
“O
utdo
or
model
name” scree
n
, then
push the
“
Set”
[
F
2
] button.
Æ
To
select th
e se
rial n
u
mb
er
of
the
ou
tdoor
unit,
s
e
le
c
t "
2
.Ser
ia
l
No.
s
e
le
c
tio
n"
.
Æ
To select t
he m
odel na
me
of the
indoor
un
it
,
select "2
. M
o
del name selection
".
Æ
To select t
he ser
ial num
ber
of t
he indo
or
unit,
s
e
le
c
t "
2
.Ser
ia
l
No.
s
e
le
c
tio
n"
.
2
Push the [
∧
] /
[
∨
] button t
o
select
“
R
emote con
troll
er”
or “Outdoor un
it”.
Æ
W
hen "Outdoo
r unit"
o
r "Indo
or unit" is s
e
le
cted,
th
e
m
ode
l nam
e or
ser
ial
n
umbe
r r
eceived fro
m
th
e out
door
or
indoo
r u
n
it is
dis
p
la
y
e
d.
Æ
W
hen "Rem
ote co
ntr
o
ller
" is selected
, the
m
anua
lly enter
ed
m
odel nam
e
o
r ser
ia
l num
ber
is displayed.
Æ
The
factor
y defa
u
lt is
"
O
u
tdoo
r u
n
it" or
"Indo
or
un
it
".
3
Push the [
MEN
U
] butto
n.
Æ
The
s
c
reen
re
tur
ns to th
e “
O
utdoo
r m
ode
l
na
me”
scre
en.
1.Manual model name input
2.Model name selection
Outdoor model name
Outdoor model name
Return
Set
Fix
Set
Return
Set
Fix
Del
A
BCDE
FGH
I
J
KLMNO
PQRST
UWXY
Z&/:·
abcde
fghij
klmno
pqrst
uvwxy
z–+!?
12345
67890
1.Manual model name input
2.Model name selection
Outdoor model name
RA
V
-SP1
104A
T8-E
Outdoor model name
Return
Set
Fix
Set
Model name selection
Remote controller
Outdoor unit
Return
Fix
Lit
e
-V
is
ion
plus Remot
e
C
ontro
ller
Installation
Manual
Ch
ecking t
h
e model name or serial numb
e
r
The m
ode
l n
ame
or
serial nu
mbe
r t
o be d
isp
la
y
e
d on
the Ou
tdoor
(
Indo
or)
m
odel na
me
or
Outdoo
r (
Ind
oor
) u
nit
ser
ia
l
No.
s
c
reen
is
dis
p
la
y
e
d.
3.
Alarm history
List of
la
test 10
alarm
da
ta: er
ror
in
for
m
ation
of che
c
k cod
e
, da
te, time, an
d unit, is displayed
.
Deleting
th
e alarm history
1
Push the [
∧
] /
[
∨
] butt
o
n t
o
select
“
3. Alarm
history
”
on the “
Field
sett
ing
me
nu
”
sc
reen, then push
the “
Set” [
F2] bu
tton.
L
is
t of latest 10
Ala
rm
d
a
ta
is displaye
d
.
*
T
he
old
est da
ta ar
e de
le
ted in
ord
er
to r
ecor
d
th
e new on
es.
Æ
The
date a
nd tim
e
when t
he er
ro
r occurr
ed
for
th
e fir
s
t time
is displayed
for
the
rep
eate
d
alar
m
.
1
Push the “
Reset”
[
F2] button
while the list o
f
alar
m
histor
y is displayed.
2
Push the “
Yes”
[
F1] button
af
ter
t
h
e
confirm
atio
n
scree
n
is displayed.
Æ
Delete t
he alar
m
his
tory in
each r
e
m
o
te
con
troller
when t
he du
al re
mote
contr
o
ller
system i
s
u
s
ed.
1.Manual model name input
2.Model name selection
Outdoor model name
RA
V
-SP1
104A
T8-E
Outdoor model name
Return
Set
Fix
A
p
pe
ar
s he
re
.
1.Test mode
2
.Register service info.
3.Alarm history
4
.Monitor function
5
.DN setting
Field setting menu
Return
Set
Set
Unit Code Date
T
ime
1. 1–2 E04 31/12/2010 12:25
2. – – – –
3. – – – –
4. – – – –
Alarm history
Return
Reset
Return
Reset all alarm data.
No
Ye
s
Alarm history
B3
Reset
Ye
s
FILE NO. SVM-
12004
–
109
–
Summary of Contents for RAV-SM307KRTP-A
Page 14: ...RAV SM806KRT E TR FILE NO SVM 12004 14 ...
Page 112: ...TOSHIBA CARRIER CORPORATION ...