– 10 –
FILE NO. SVM-1
4059
Explanations given to user
s
If you have discovered that the fan grille is damaged, do not approach the outdoor unit but set the circuit breaker
to the OFF position, and contact a qualified service person to have the repairs done.
Do not set the circuit breaker to the ON position until the repairs are completed.
Relocation
s
Only a qualified installer (
1) or qualified service person (
1) is allowed to relocate the air conditioner.
It is dangerous for the air conditioner to be relocated by an unqualified individual since a fire, electric shocks,
injury, water leakage, noise and/or vibration may result.
s
When carrying out the pump-down work shut down the compressor before disconnecting the refrigerant pipe.
Disconnecting the refrigerant pipe with the service valve left open and the compressor still operating will cause air,
etc. to be sucked in, raising the pressure inside the refrigeration cycle to an abnormally high level, and possibly
resulting in reputing, injury, etc.
(
1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”
Declaration of Conformity
TOSHIBA CARRIER (THAILAND) CO., LTD.
144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road,
Amphur Muang, Pathumthani 12000, Thailand
Manufacturer:
Nick Ball
Representative/TCF holder:
Toshiba EMEA Engineering Director
Toshiba Carrier UK Ltd.
Porsham Close, Belliver Industrial Estate,
PLYMOUTH, Devon, PL6 7DB.
United Kingdom
Authorized
Hereby declares that the machinery described below:
Generic Denomination:
Air Conditioner
Model/type:
Commercial name:
Digital Inverter Series Air Conditioner
Complies with the provisions of the “Machinery” Directive (Directive 2006/42/EC) and the regulations transposing
into national law.
Complies with the provisions of the following harmonized standard:
EN 378-2: 2008 + A2:2012
Note:
This declaration becomes invalid if technical or operational modifications are introduced without the
manufacturer’s consent.
Disposal
How to dispose of air conditioners with a rating of 12 kW and below in accordance with the 2002/96/EC Directive
WEEE (Waste Electrical and Electronic Equipment) is provided in the Installation Manual supplied with your product.
For disposal of the product above 12 kW in rating you should use a registered company in accordance with any
national or EU legislation.
<Model names with a rating of 12 kW and below (outdoor units)>
DI series
RAV-SM
30
4ATP-E, RAV-SM
4
04ATP-E,
SVM-13072.indb 10
SVM-13072.indb 10
11/01/13 1:53 PM
11/01/13 1:53 PM
RAV-SM
30
4AT
J
P-E,
RAV-SM
4
04AT
J
P-E,
RAV-SM
30
4ATP-
TR
,
RAV-SM
4
04ATP-
TR
RAV-SM
30
4ATP-E, RAV-SM
4
04ATP-E,
RAV-SM
30
4AT
J
P-E,
RAV-SM
30
4ATP-
TR
,
RAV-SM
4
04AT
J
P-E,
RAV-SM
4
04ATP-
TR
Summary of Contents for RAV-SM304ATJP-E
Page 17: ... 17 FILE NO SVM 14059 2 CONSTRUCTION VIEWS EXTERNAL VIEWS 2 1 RAV SM304AT P SM404AT P ...
Page 21: ... 21 FILE NO SVM 14059 4 WIRING DIAGRAM 4 1 RAV SM304AT P ...
Page 22: ... 22 FILE NO SVM 14059 4 2 RAV SM404AT P ...
Page 41: ... 41 FILE NO SVM 14059 7 2 Outdoor Print Circuit Board RAV SM304AT P SM404AT P MCC 1656 ...
Page 84: ...FILE NO SVM 14059 13 EXPLODED VIEWS AND PARTS LIST 13 1 RAV SM304ATP E RAV SM304ATP TR 84 ...
Page 86: ...FILE NO SVM 14059 Inverter assembly SM30 86 ...
Page 88: ...FILE NO SVM 14059 13 2 RAV SM404ATP E RAV SM404ATP TR 88 ...
Page 90: ...FILE NO SVM 14059 Inverter assembly SM40 90 ...
Page 92: ...FILE NO SVM 14059 13 3 RAV SM304ATJP E 92 ...
Page 94: ...FILE NO SVM 14059 Inverter assembly SM30 94 ...
Page 96: ...FILE NO SVM 14059 13 4 RAV SM404ATJP E 96 ...