Installation Manual
‒
15
‒
15-EN
Installation of eletrical cover 2 holes type
REQUIREMENT
In case of group control, electrical cover 1 hole type need to change to electrical cover 2 holes type.
●
Step to remove the electrical cover 1 hole.
1) The electical cover 1 hole can be removed by removing the screw securing the electical cover 1 hole
and them pulling out the electical cover 1 hole.
Remove the screw 1 part.
2) Remove the electrical cover 1 hole by direction backside of unit.
Direction to remove
3) Remove the EDGE-SADDLE take off from electrical cover 1 hole.
Direction to remove
●
Step to install the electrical cover 1 hole (Option connect power supply 2 holes)
1) Install the EDGE-SADDLE to
electrical cover 1 hole
2) Install the electrical cover 1 hole
to unit
3) Insert the screw.
Make sure to
fi
x pin
on position lock.
Direction to remove
Direction to remove
Make sure screw 1 part
fi
x on position.
01_1130850102-EN.indd 15
01_1130850102-EN.indd 15
7/3/2565 BE 17:15
7/3/2565 BE 17:15