– 33 –
Concealed Duct High Static Pressure
Installation Manual
Procedure
6
If there is other indoor unit to be changed, repeat procedure
2
to
5
to change the setup.
When the above setup has finished, push
to select
the indoor UNIT No. before change of setup, specify CODE
No. [
12
], [
13
], [
14
] in order with TEMP.
/
buttons,
and then check the changed contents.
Address change check Before change:
[
3-3-1
]
→
After change: [
2-2-2
]
Pushing
button clears the contents of which setup was
changed.
(In this case, procedure from
2
is repeated.)
Procedure
7
After check of the changed contents, push
button. (Setup
is determined.) When pushing
button, the display
disappears and the status becomes the usual stop status.
(When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
* If the operation from the remote controller is not accepted
even 1 minute or more passed after pushing
button, it
is considered that the address setup is incorrect.
In this case, the automatic address must be again set up.
Therefore repeat procedure of the setup change from
the Procedure
1
.
To recognize the position of the
corresponding indoor unit though the
indoor UNIT No. is known
Check the position during operation stop.
(Be sure to stop operation of the set.)
Procedure
1
Push simultaneously
+
buttons for 4 seconds or
more.
After a while, the display part flashes and the display appears
as shown below.
In this time, the position can be checked because fan of the
indoor unit operate.
• For the group control, the indoor UNIT No. is displayed as
[
] and fans of all the indoor units in the group control
operate.
Check the displayed CODE No. is [
01
].
• When the CODE No. is other than [
01
], push
button to
erase the display and repeat procedure from the first step.
(After pushing
button, operation of the remote controller
is not accepted for approx. 1 minute.)
Procedure
2
In the group control, every pushing
button, the
indoor UNIT No. in the group control is displayed in order.
In this time, the position of the indoor unit can be confirmed
because only fan of the selected indoor unit operate.
(For a group control, No. of the firstly displayed indoor unit
becomes the header unit.)
Procedure
3
After confirmation, push
button to return the mode to the
usual mode.
When pushing
button, the display disappears and the
status becomes the usual stop status.
(When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
Indoor UNIT No. before setup change is displayed.
2
1,3
1
(* Display changes according to
the model No. of indoor unit.)
33-EN