![Toshiba RAV-HM301MUT-E Service Manual Download Page 107](http://html.mh-extra.com/html/toshiba/rav-hm301mut-e/rav-hm301mut-e_service-manual_1135233107.webp)
– 107 –
No. Part name
Procedure
Remarks
TA sensor
1. Detachment
1) Remove the panel, electric parts box cover, wiring
cover and wiring fixing plate.
(Refer to
f
-1,
d
-1,
i
-1-2,
i
-1-3.)
2) Disconnect TA sensor connector (CN104 Yellow, 2P)
which is connected to the control P.C. board, and take
off the lead wire from the clamp.
3) Remove the screw of the TA sensor cover.
(M 4 × 10, 1pc.)
4) Remove TA sensor from the TA sensor fixed
implement.
2. Attachment
1) Fix TA sensor to TA sensor fixing implement, and fix
the TA sensor cover with screw.
(M 4 × 10, 1 pcs, M 4 × 8, 1 pcs.)
2) Perform wiring of TA sensor as original.
Adjust position of the tube so that the tube of
TA sensor will be included in the cover.
Fixing screw
TA sensor cover
TA sensor
fixing bracket
TA sensor
Wiring fixing plate
Fixing screw
(M 4 × 8)
Fixing screw
(M 4 × 10)
Groove for wiring
of the drain pan