– 20 –
Model name
Indoor Unit
RAV-RM
401MUT-E
561MUT-E
Appearance
Main Unit
Zinc hot dipping steel plate
* Heat-insulating material attached to only upper plate
Air filter
Standard filter (Long life filter)
Drain port (Nominal dia. mm)
VP20 (Polyvinyl chloride tube)
Electrical
characteristics
(*1)
Cooling
Running current
A
4.69 - 4.30
0.95
92
3.79
4.74 - 4.35
0.96
92
4.17
15.0
7.26 - 6.66
1.55
97
3.23
7.17 - 6.57
1.53
97
3.66
13.6
Sound pressure level
Cooling/Heating
dB(A)
45 / 47
47 / 48
Sound power level
Cooling/Heating
dB(A)
62 / 64
63 / 64
Pipe connections
Gas / Liquid
mm
Ø 12.7 / Ø 6.4
Min. Length
m
5
Operation Range
Cooling
˚C
-15 to 43
Heating
˚C
-15 to 15
-20 to 15
Max. Length
m
30
Chargeless
m
20
Max. height difference
m
30
Weight
kg
40
44
Outer dimension
H x W x D
mm
550 x 780 x 290
Refrigerant ( Type / Charge weight (kg) )
R410A / 1.0
R410A / 1.4
Sound pressure level High ( M+ / M / L+ / L )
dB(A)
41 ( 38 / 36 / 33 / 32 )
44 ( 42 / 39 / 36 / 35 )
Sound power level High ( M+ / M / L+ / L )
dB(A)
56 ( 53 / 51 / 48 / 47 )
59 ( 57 / 54 / 51 / 50 )
Standard air flow ( M+ / M / L+ / L )
m³/h
660(610/552/480/468)
798(720/672/562/546)
Motor
W
60
Fan unit
Fan
Turbo fan
Heat exchanger
Finned tube
Outer dimension Main unit
H x W x D (*3)
mm
256 x 575 x 575
Ceiling panel
(Sold Separately)
H x W x D (*3)
mm
12 x 620 x 620
Weight
Main unit
kg
15.0
Ceiling panel (Sold Separately)
kg
2.5
Ceiling panel
(Sold Separately)
Model name
RBC-UM21PG(W)-E
Color
Gran White (Mansell 5PB9/1)
Power consumption
kW
Power factor
%
EER
Heating
Running current
A
Maximum current
Indoor Unit
Outdoor Unit
Power consumption
kW
Power factor
%
COP
Cooling capacity (Rated (Min.-Max.))
kW
3.6 (1.5 - 4.0)
5.0 (1.2 - 5.6)
Heating capacity (Rated (Min.-Max.))
kW
4.0 (1.5 - 5.0)
Power supply
1phase 50Hz 230V(220V-240V)
5.6 (0.9 - 7.4)
Outdoor Unit
RAV-SP
404ATP-E
564ATP-E
SDI combination (R410A)
<Single type>
*1 : The Cooling capacity and electrical characteristics are measured under the conditions specified by JIS B
8615-1 based on the reference piping.
The reference piping consists of 5m of main piping and 2.5m of branch piping connected with 0 meter
height.
*2 : The sound level are measured in an anechoic chamber in accordance with JIS B 8616. Normally, the
values measured in the actual operation environment become larger than the indicated values due to the
effects of external sound.
*3 : Height from the ceiling. Depth doesn't include the electric parts box.
Notes ;
Rated conditions Cooling : Indoor air temperature 27°CDB/ 19 °CWB, Outdoor air temperature 35°CDB
Heating : Indoor air temperature 20°CDB, Outdoor air temperature 7°CDB/ 6°CWB