-10-
4.2. RAV-163TUH-PE
No.
PARTS NAME
TYPE
SPECIFICATIONS
1
Indoor unit fan motor (x2)
PAF-230-7-4
Output (Rated) 7W, 4 pole, 1 phase, 230V, 50Hz
2
Running capacitor for
indoor fan motor (x2)
EVM45M504UF
AC 450V, 0.5µF
3
Transformer (Indoor unit)
ST-9586
AC187~264V
4
Stepper motor (x2)
MP35EA2
DC12V, 80mNm
5
Relay
LY2F
AC 240V, 2ab
6
Drain pump
PCD-4N230TF-7
AC230V, 0.2A
7
Float switch
FS-085-003E
AC230V, 0.5A
8
Sensor for room
temperature
Maximum input
38mA
°C
15
20
25
30
40
16.1
12.6
10.0
8.0
5.2
9
Indoor unit sensor for
heat- exchanger
temperature.
DTN-C103J40
Maximum input
34mA
°C
–12
0
25
50
62.29
32.82
10.0
3.59
4.1 RAV-103TUH-PE, RAV-133TUH-PE
No.
PARTS NAME
TYPE
SPECIFICATIONS
1
Indoor unit fan motor (x2)
PAF-230-7-4
Output (Rated) 7W, 4 pole, 1 phase, 230V, 50Hz
2
Running capacitor for indoor
fan motor (x2)
EEP2H105HQA105
AC 500V, 1.0µF
3
Transformer (Indoor unit)
ST-9586
AC187~264V
4
Stepper motor (x2)
MP35EA2
DC12V, 80mNm
5
Relay
LY2F
AC 240V, 2ab
6
Drain pump
PCD-4N230TF-7
AC230V, 0.2A
7
Float switch
FS-085-003E
AC230V, 0.5A
8
Sensor for room temperature
Maximum input
38mA
°C
15
20
25
30
40
16.1
12.6
10.0
8.0
5.2
9
Indoor unit sensor for heat-
exchanger temperature.
DTN-C103J40
Maximum input
34mA
°C
–12
0
25
50
62.29
32.82
10.0
3.59
K
Ω
K
Ω
K
Ω
4. SPECIFICATION OF ELECTRICAL PARTS
K
Ω
Summary of Contents for RAV-103TUH-PE