– 36 –
Item
8. Louver
control
(Continued)
Operation flow and applicable data, etc
De
s
cription
<<Selection of Swing mode>>
* Select the louver swing type from the standard swing, dual swing or
cyclic swing.
Carry out the setting operation while the indoor unit is stopped. (Turn
off the air conditioning unit before starting the setting operation.)
Before setting
Louver setting
1.Swing type
2.Louver lock
Return
Set
Swing type
Return
Fix
Standard
Dual
Cycle
Selection of Swing mode
can be set up by wired
remote controller.
1
Push the [
] / [
] button to select
“3. Louver setting” on the menu screen, then push the
“
Set” [ F2] button.
2
Push the [
] / [
] button to select
“1.Swing type”, then push the “
Set” [ F2]
button.
3
Push the [
] / [
] button on the “Swing type”
screen to select the swing type.
→
Refer to the Owner’s Manual supplied with the indoor unit
about the swing type.
4
Push the [
MENU] button.
→
“ Setting” appears on the display.
→
The unit selection screen appears when the group control is
used. Push the [
CANCEL] button on the unit selection
screen to finish the setting operation. “ Setting” appears on
the display.