• Do not use any refrigerant different from the one speci

fi

 ed for complement or 

replacement.

  Otherwise, abnormally high pressure may be generated in the refrigeration 

cycle, which may result in a failure or explosion of the product or an injury to 
your body.

• Do not use means to accelerate the defrosting process or to clean, other than 

those recommended by the manufacturer.

• The appliance shall be stored in a room without continuously operating ignition 

sources (for example: open 

fl

 ames, an operating gas appliance or an operating 

electric heater).

• Be aware that refrigerants may not contain an odour.
• Do not pierce or burn as the appliance is pressurized. Do not expose the 

appliance to heat, 

fl

 ame, sparks, or other sources or ignition. Else, it may 

explode and cause injury or death.

• For R32 model, use pipes, 

fl

 are nut and tools which is speci

fi

 ed for R32 

refrigerant. Using of existing (R22) piping, 

fl

 are nut and tools may cause 

abnormally high pressure in the refrigerant cycle (piping), and possibly result in 
explosion and injury.

• Thickness of copper pipes used R32 must be more than 0.8mm. Never use 

copper pipes thinner than 0.8mm.

• Do not perform 

fl

 are connection inside a building or dwelling or room, when 

joining the heat exchanger of indoor unit with interconnection piping. Refrigerant 
connection inside a building or dwelling or room must be made by brazing or 
welding. Joint connection of indoor unit by 

fl

 aring method can only be made 

at outdoor or at outside of building or dwelling or room. Flare connection may 
cause gas leak and 

fl

 ammable atmosphere.

• After completion of installation or service, con

fi

 rm there is no leakage of 

refrigerant gas. It may generate toxic gas when the refrigerant contacts with 

fi

 re.

• Appliance and pipe-work shall be installed, operated and stored in a room with a 

fl

 oor area larger than A

min

 m

2

.

  How to get A

min

 m

2

 :  A

min

 = (M / (2.5 x 0.22759 x h

0

))

2

  M is the refrigerant charge amount in appliance in kg. h

0

 is the installation height 

of the appliance in m: 0.6 m for 

fl

 oor standing/1.8 m for wall mounted/1.0 m for 

window mounted/2.2 m for ceiling mounted (For these units recommend 
installation height 2.5 m.).

• Comply with national gas regulations.

Summary of Contents for RAS-M10PKVPG-E

Page 1: ...R CONDITIONER MULTIPLE TYPE INSTALLATION MANUAL 1121451199 R32 ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY HRVATSKI MAGYAR NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA LIETUVIŲ PУCСКИЙ ...

Page 2: ...ole and Mounting Installation Plate 7 Piping and Drain Hose Installation 8 Indoor Unit Fixing 9 In case of Indoor unit is fixed to Installation plate with screws 9 Drainage 9 ELECTRICAL WORKS 10 Wiring Connection 10 Connecting Cable Connection 11 OTHERS 12 Gas Leak Test 12 Remote Control A B Selection 12 Test Operation 12 Auto Restart Setting 12 CONTENTS EN ...

Page 3: ...oes not require admission or repeated hospital treatment 2 Property damage means greater damage which affects assets or resources For general public use Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations This appliance must b...

Page 4: ...ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNACE ...

Page 5: ...d possibly result in explosion and injury Thickness of copper pipes used R32 must be more than 0 8mm Never use copper pipes thinner than 0 8mm Do not perform flare connection inside a building or dwelling or room when joining the heat exchanger of indoor unit with interconnection piping Refrigerant connection inside a building or dwelling or room must be made by brazing or welding Joint connection...

Page 6: ...ter or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause of fire Do not install in a place that can increase ...

Page 7: ...ipple 1 for heating model only 8 Cap water proof 2 for some models only 9 Owner s Manual Installation Manual B Label 2 for Multi model The part may differ from that shown The number of parts may differ by model The part is packed with the outdoor unit Filter Clean Replacement Air filters Clean every 2 weeks 1 Open the air inlet grille 2 Remove the air filters 3 Vacuum or wash and then dry them 4 R...

Page 8: ...d wall and tilt the indoor unit for better operation For the rear left and left piping Wall 1 Batteries Flat head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Shield pipe Attach to the front panel Air filter Hook Installation plate Hook 52 mm or more 190 mm or more 225 mm or more Insulate the refrigerant pipes separately with insulati...

Page 9: ... a concrete wall with anchor bolts use the anchor bolt holes as illustrated in the below figure 3 Install the installation plate horizontally in the wall When installing the installation plate with a mounting screw do not use the anchor bolt holes Otherwise the unit may fall down and result in personal injury and property damage 1 After determining the pipe hole position on the mounting plate Æ dr...

Page 10: ...fter passing the connecting pipe through the pipe hole connect the connecting pipes to the auxiliary pipes and wrap the facing tape around them Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Indoor unit Connecting cable Auxiliary pipes Installation plate Carefully arra...

Page 11: ...age 1 Run the drain hose sloped downwards 2 Put water in the drain pan and make sure that the water is drained out of doors 3 When connecting extension drain hose insulate the connecting part of extension drain hose with shield pipe NOTE The hole should be made at a slight downward slant on the outdoor side Arrange the drain pipe for proper drainage from the unit Improper drainage can result in de...

Page 12: ...l cords into the pipe hole on the wall 4 Take out the cable protrudes about 20 cm from the front 5 Insert the cable fully into the terminal block and secure it tightly with screws 6 Tightening torque 1 2 N m 0 12 kgf m 7 Secure the cable with the cord clamp 8 Fix the terminal cover and attach front panel to the indoor unit Cable about 20 cm Front panel Terminals block Main panel Terminal cover Wir...

Page 13: ...al Block Chassis CAUTION 1 The power supply must be same as the rated of air conditioner 2 Prepare the power source for exclusive use with air conditioner 3 Circuit breaker must be used for the power supply line of this air conditioner 4 Be sure to comply power supply and connecting cable for size and wiring method 5 Every wire must be connected firmly 6 Perform wiring works so as to allow a gener...

Page 14: ...r adjacent two rooms if operating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setti...

Reviews: