36
Indoor unit
Wipe with a soft cloth.
•
Wipe with a soft cloth with warm water (less than 40 °C) and please dry well.
Remote control
Wipe with a soft cloth.
•
Do not wash with water. It may cause damage.
Notes
•
Do not use alcohol, petroleum, thinners, glass cleaner or polishing
powder. These may damage the product.
•
Do not rub or touch for a long period with a chemical wipe. It may
cause deterioration or stripping of materials.
Air filter
After using about 2 weeks, please clean it. When the air filter is blocked, the
efficiency of air conditioner may be decreased.
Clean with a vacuum cleaner or wash in water.
•
When washing in water, please dry well.
■
How to remove air filter.
1.
Lift the front panel until it stops.
2.
Raise handle of the lower air filter and pull out.
•
At the time of fixing; When replacing the air filter, insert it in the indoor unit
and snap into place using the filter control guide and close the front panel.
Air filter
Filter control guide
How to open the front panel
Pull the lower levers at the right and left side toward you and lift them
up until fixed and stop.
※
Beware an arm of the front panel might come off and fall.
How to remove the front panel
Pull and lift up front panel until it stops, move arms on left and right side to
outward direction then pull toward you to remove front panel.
※
Beware a piece of the front panel might come off and fall.
Arm
Arm
How to attach the front panel
Reverse the procedure to attach the front panel.
Keep front panel horizontal and put both arms into guides.
Make sure both arms are inserted completely.
If the gap between main panel and front panel isn’t even, remove and attach again.
Arm
Main panel
Guide
Front panel
How to close
Pull the front panel downward, push three portions on the upper side of air outlet
to close the front panel.
Care and cleaning
Warning
•
Do not wash inside air conditioner yourself.
If washing inside the air conditioner is necessary, please request service from the supplying
retail dealership. If the inside is washed incorrectly, parts damage may occur or if insulation
of electrical parts is damaged by water leakage, electric shocks or fires are possible.
Normal care : Turn off power supply before checking or
cleaning.
Inspect air conditioner regularly to ensure efficient operation