background image

7

EN

ENGL

ISH

FR

ANÇAIS

DEUTSC

H

IT

ALIANO

ESP

AÑOL

ΕΛΛΗΝΙΚΗ

POR

T

UGUÊS

#

##SW

###

#

##R

U#

##

Preparing the filters

a

Open the air inlet grille, and remove the air filters.

b

Attach the supplied Zeolite-plus filter.

Location of the remote control

• Keep the remote control where its signals can reach the receiver of the indoor unit 

(a distance of up to 7 m is allowed).

• When you select timer operation, the remote control automatically transmits a 

signal to the indoor unit at the specified time.
If you keep the remote control in a location where proper signal transmission is 
blocked, a time lag of up to 15 minutes may occur.

Remote control holder

Installing the remote control holder

• Before you actually install the remote control holder on a wall or pillar, check 

whether the remote control signals can be received by the indoor unit.

Mounting and removing the remote control

• To mount the remote control, hold it parallel to the remote control holder and push 

it in fully. To remove the remote control, slide the remote control upwards and out 
from the holder.

USING THE REMOTE CONTROL

CAUTION

• The air conditioner will not operate if curtains, doors or other objects block the signals from the remote control to the indoor 

unit.

• Be careful that liquids do not spill onto the remote control.
• Do not expose the remote control to direct sunlight or heat. 

If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly.
Use curtains to prevent sunlight from reaching the receiver.

• Signals may not be properly received, if the room using the air conditioner has fluorescent lighting with electronic starters. If 

you are planning on using fluorescent lamps, consult with your local dealer.

• If other electrical appliances are activated by the remote control, move these appliances or consult with your local dealer.

Zeolite-plus filter

Air filters

7 m

Summary of Contents for RAS-B10EKVP-E

Page 1: ... RAS M14EACV E RAS M18EACV E Thank you for purchasing this TOSHIBA Air Conditioner Please read this owner s manual carefully before using your Air Conditioner Avant tout merci d avoir porté votre choix sur un climatiseur TOSHIBA Veuillez lire attentivement ce mode d emploi avant de mettre en service le climatiseur Wir danken Ihnen für den Kauf dieses TOSHIBA Klimageräts Lesen Sie die Bedienungsanl...

Page 2: ... INDICATEURS DE LA TELECOMMANDE 5 PREPARATION ET VERIFICATION AVANT UTILISATION 5 UTILISATION DE LA TELECOMMANDE 7 FONCTIONNEMENT AUTOMATIQUE 8 FONCTIONNEMENT AUTOMATIQUE PERMUTATION AUTOMATIQUE 8 REFROIDISSEMENT CHAUFFAGE 9 DESHUMIDIFICATION 9 VENTILATEUR SEULEMENT modèles refroidissement seulement 9 MODE PURE 10 MODE Hi POWER 11 MODE MINUTERIE 11 MODE MEMOIRE PREREGLAGE 13 REGLAGE DU SENS DU FLU...

Page 3: ...ric shock fire and so on Do not spill water or other liquid on the indoor unit If the unit is wet it can cause an electric shock Do not attempt to move or repair the unit by yourself Since there is high voltage inside the unit you can get an electric shock when removing the cover and main unit Always ask the dealer to move the air conditioner for re installing it in another place If it is improper...

Page 4: ...e Do not touch the operation buttons with wet hands Doing so could cause an electric shock Do not place any combustion device in a place where it is directly exposed to wind from the air conditioner Doing so could cause incomplete combustion When the air conditioner will not be used for an extended period of time turn off the main switch or the circuit breaker for added safety Disconnecting from t...

Page 5: ... c TIMER indicator Yellow d PURE indicator Blue e OPERATION indicator Green The operation indicators flash rapidly five times per second when a safety protection feature is activated f S CLEAN indicator Green When the unit shuts down after having operated for 10 or more minutes in the cooling or dry mode the cleaning operation is started automatically and the S CLEAN indicator on the unit s displa...

Page 6: ...r times To move up the time press of the ON button To move down the time press of the ON button i OFF timer button OFF Use this button to change the OFF timer times To move up the time press of the OFF button To move down the time press of the OFF button j Reserve button SET Press this button to store the time settings A receiving beep is heard k Cancel button CLR Press this button to cancel the O...

Page 7: ...during operation The mark is shown when holding down the button for more than 3 seconds while the mark is flashing Press another button to turn off the mark i ECO indicator Indicates when the ECO is activated Press the ECO button to start and press it again to stop operation j A B change indicator remote control When the remote control switching function is set B appears in the remote control disp...

Page 8: ...control the clock panel displays AM 0 00 and flashes a ON button Press the ON button to set the current time Each press of the ON button changes the time in one minute increments Holding down the ON button changes the time in ten minute increments b SET button Press the SET button The current time is displayed and the clock starts Adjusting the clock a CLOCK button Press the CLOCK button The clock...

Page 9: ... remote control To mount the remote control hold it parallel to the remote control holder and push it in fully To remove the remote control slide the remote control upwards and out from the holder USING THE REMOTE CONTROL CAUTION The air conditioner will not operate if curtains doors or other objects block the signals from the remote control to the indoor unit Be careful that liquids do not spill ...

Page 10: ...n you set the air conditioner to A mode or switch over from AUTO operation because of a change in settings the air conditioner automatically selects cooling heating heat pump models only or fan only operation depending on the room temperature see page 16 Start a button Press this button to start the air conditioner b Mode select button MODE Select A c Temperature button Set the desired temperature...

Page 11: ...ndicator green on the display panel of the indoor unit turns on and operation starts after approximately 3 minutes Stop button Press this button again to stop the air conditioner Start a button Press this button to start the air conditioner b Mode select button MODE FAN ONLY c Fan speed button FAN Select one of AUTO LOW LOW MED MED HIGH The OPERATION indicator green on the display panel of the ind...

Page 12: ...ON The air ionizer starts in conjunction with air purifying operation During the air purifying operation a small amount of ozone is produced and you might notice the smell When the air flow is automatic it changes between LOW and MED LOW operation is performed when the indoor air becomes clean During operation the position of the vertical air flow louvers may change if the room temperature is low ...

Page 13: ...e in one hour increments b SET button Press the SET button to set the timer The timer time is displayed and the timer starts c CLR button Press the CLR button to cancel the timer setting Once you select timer operation mode the settings are saved in the remote control Thereafter the air conditioner will start operating under the same conditions as if you pressed the or button of the remote control...

Page 14: ...conditioner may stop operating Daily combined timer setting the ON and OFF timers simultaneously and activating every day This feature is useful when you want to use the combined timers at the same time every day Setting combined TIMER 1 Press the ON button to set the ON timer 2 Press the OFF button to set the OFF timer 3 Press the SET button 4 After step 3 an arrow mark or flashes for about 3 sec...

Page 15: ...led Operation modes which can be stored with the MEMO button are MODE Temperature FAN TIMER and Hi POWER To operate the air conditioner with the setting stored using the MEMO button a PRESET button Press the PRESET button The setting stored with the MEMO button will be shown and the air conditioner operates based on the setting A When the PRESET button is pressed while operation is stopped The OPE...

Page 16: ...nge the swing direction press the FIX button Adjusting the horizontal air flow Preparation Grasp the lever on the horizontal air flow louver and move them to adjust the air flow direction as required You can adjust the air flow at the left and right locations of the grilles ADJUSTING AIR FLOW DIRECTION CAUTION The FIX and SWING buttons will be disabled when the air conditioner is not operating inc...

Page 17: ...use the remote control to restart the air conditioner During the subsequent operation the green indicator is turned on The auto restart operation will not accept a command if timer operation with the remote control is activated After restarting the air conditioner by the AUTO RESTART OPERATION the louver swing AUTO operation does not resume To cancel the auto restart operation proceed as follows R...

Page 18: ...operating condition ECO operation When you press the ECO button during cooling heating or A operation the air conditioner starts the following operation The fan speed is controlled automatically Cooling operation In the minimum operation zone where the air conditioner is operated at minimum capacity overcooling is prevented by raising the temperature setting The room temperature is thus regulated ...

Page 19: ...10 seconds to start the cooling operation Cleaning operation This function is used to dry the inside of the air conditioner to reduce the growth of mold etc inside the air conditioner When the unit shuts down after having operated for 10 or more minutes in the cooling or dry mode the cleaning operation is started automatically and the S CLEAN indicator on the unit s display panel turns on Cleaning...

Page 20: ...it up slightly and then pull it downward to take it out from the filter holder 3 Use a vacuum cleaner to remove the dust from the filters or wash them with water After washing the air filters dry them in the shade USUAL MAINTENANCE WARNING Before you clean the air conditioner be sure to turn off the circuit breaker or main power switch CAUTION Use a dry cloth to wipe the indoor unit and remote con...

Page 21: ...tallic scrubbing brush or other hard brushes Use of such hard objects will cause scratches on the surface of the grille and the metal coating to peel off If extremely dirty clean the air inlet grille with a neutral kitchen detergent and rinse it off with water 3 Wipe off the water from the air inlet grille and dry it 4 Fit the left and right arms of the air inlet grille to the shafts on the two si...

Page 22: ...cuum cleaner to remove the dirt before washing with water Also be sure to always use clean water when washing If dirty water is used the debris in the water can adhere to the filter Do not rub the filter surface In the final of the water washing be sure to always rinse the filter with clean water If the filter is particularly dirty add a neutral detergent at the standard concentration and then rin...

Page 23: ... turns on during the night the air conditioner can still be used until the morning without a problem but be sure to perform cleaning as soon as possible Preparation 1 Turn off the power supply 1 Open the air inlet grille Lift up the air inlet grille until it clicks into place 2 Grasp the left and right handles of the air filter and lift up slightly and then pull downward to remove the filter from ...

Page 24: ...l the way in Press both ends of the plasma pure filter in the direction of c until the protrusions on both sides of the plasma pure filter are completely inserted into the holders Press in the plasma pure filter until the protrusions on both sides are completely inserted into the holders If installation is incomplete the FILTER indicator orange may light 6 Attach the air filter and then close the ...

Page 25: ...ated snow Select the position for the outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris It is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance During the heating mode and at sub zero temperatures the water drained off the outdoor unit as a result of the automatic def...

Page 26: ...ollowing points Recheck Inoperative The power main switch is turned off The circuit breaker is activated to cut off the power supply The main power fuse has blown The electric current has stopped The batteries in the remote control used up The ON timer is set As a protective mechanism for the air conditioner it does not operate for three minutes immediately after restarting operation or turning on...

Page 27: ...p models Water is drained from the outdoor unit Frost sometimes forms on the outdoor unit during heating operation In that case the unit automatically performs defrosting for 2 to 10 minutes for improving the heating efficiency In the defrosting operation the airflow from both the indoor and outdoor units stops A hiss sound is heard when the flow of the refrigerant is changed for defrosting The wa...

Page 28: ...hen it is dirty When the power is turned on or the air conditioner is stopped the vertical air louvers may make a rattling sound or shuttling sound Some parts may expand or shrink due to temperature fluctuations and this can result in a slapping sound When the refrigerant is flowing a hissing sound or gurgling sound can result A buzzing sound is sometimes made from the air ionizer A hissing sound ...

Page 29: ... 3 2 4 2 Cooling current A AMP 0 15 2 48 2 26 0 15 4 25 3 89 Cooling power W WATT 30 520 30 890 Heating current A AMP 0 15 3 25 2 96 0 15 4 52 4 13 Heating power W WATT 30 680 30 1 060 Dimensions Width mm 790 780 790 780 Height mm 250 550 250 550 Depth mm 215 290 215 290 Net weight kg 9 35 9 37 Type Reverse cycle Split type Model Indoor Unit Outdoor Unit RAS B16EKVP E RAS 16EAVP E Power supply 220...

Page 30: ...shown on the display The air conditioner stops since the setting time has elapsed The TIMER display turns off after a certain period of time Check whether the timer operation has started when the ON TIMER is shown on the display When the time reaches the time setting for the ON timer operation the air conditioner starts to operate automatically and the ON timer display turns off The Signal Receivi...

Page 31: ...en 416 8521 Japan declare under our responsibility that the product Household split type Room Air Conditioner to which this declaration relates is in conformity with the provisions of Council Directive 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage Directive E075003432 a ...

Reviews: