Item
3. Outdoor fan
motor control
Operation flow and applicable data, etc.
The blowing air volume at the outdoor unit side is controlled.
Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.
* For the fan motor, a DC motor with non-stage variable
speed system is used. However, it is limited to 8 stages for
reasons of controlling.
Description
1) The operation command sent
from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.
2) When strong wind blows at
outdoor side, the operation of air
conditioner continues with the
fan motor stopped.
3) Whether the fan is locked or not
is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.
4) According to each operation
mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.
2) Fan speed
≥
400
when the motor stopped.
Air conditioner ON
(Remote controller)
YES
YES
NO
NO
Indoor unit controller
Fan motor ON
3) Fan lock
OFF status of
fan motor continues.
4) Motor operates as shown in the table below.
1) Outdoor unit
operation
command
(Outdoor
fan
control)
Air conditioner
OFF
Alarm
display
Outdoor fan speed (rpm)
~ 31.7
Compressor speed (rps)
To > 1
0
°C
To
To < 1
0
°C
To < 5°C
To
<
−
3
°C
When To is abnormal
Hz<
16.8
16.8
≤
Hz
≤
48.6
48.
6<Hz~
MAX
f
7
f 8
f 9
f
9
f
B
f
E
f
E
f
E
f
E
f
E
f
E
f
E
f
F
f
F
f
F
In Heating operation
32.4
≤
Hz
RAS-
B
16BKVG-E
Hz<13.8
13.8
≤
Hz<32.4
30.6
≤
Hz
MIN
MAX
MIN
MAX
MIN
MAX
f6
fB
f8
fE
fA
fE
f5
fA
f7
fE
f9
fE
f3
f7
f5
f9
f7
fB
To
f2
f5
f4
f7
f6
f9
f1
f3
f3
f5
f4
f7
f1
f2
f2
f4
f3
f5
When To is abnormal
OFF
fB
OFF
fE
f1
fE
To
≥
5.5 °C
To
≥
0 °C
To<0 °C
Compressor speed (rps)
In cooling operation
To
≥
38 °C
To
≥
28 °C
To
≥
15 °C
Model
Hz<13.8
RAS-
B
05,07BKVG-E
RAS-
B
10,13BKVG-E
13.8
≤
Hz<30.6
Tap
RAS-
B
05BKVG-E
RAS-
B
07BKVG-E
RAS-
B
10BKVG-E
RAS-
B
13BKVG-E RAS-
B
16BKVG-E
f0
0
0000
f1
300
300
300
300
200
f2
370
370
370
370
300
f3
390
390
390
390
300
f4
460
460
460
460
360
f5
500
500
500
500
440
f6
520
520
520
520
500
f7
620
620
620
620
550
f8
720
720
720
720
600
f9
750
750
750
750
650
fA
780
780
780
780
700
fB
780
780
780
780
700
fC
880
880
880
880
800
fD
880
880
880
880
850
fE
880
880
900
950
900
fF
880
880
900
950
950
RPM
0
0
0
FILE NO. SVM-18006