– 36 –
Item
10. Air purifying
control
Operation flow and applicable data, etc.
This function generates nagative ion while cleaning
the air in the room.
If air purifier-ON signal is received while the air
conditioner stops, the air purifier starts operation, and
if it is received while the air conditioner operates, the
air conditioner and the air purifier start operation.
The air ion generator operates linked with the air
purifying operation.
Description
Sending air purifier-ON
Operation lamp ON
Fan ON
Air purifier ON
Air purifying operation
Start of air purifier-ON
Operation lamp OFF
Filter-OFF
Memory position
of louver/COOL
Air condi
air purifier operate
Fan stop
Air purifier-OFF
Louver close
All stop
Air conditioner operates
Sending air purifier-OFF
1
,
2
3
1
2
3
4
,
4
Air conditioner operates
Air conditioner stops
Air purifier operates
Air condi
Air purifier operate
*1
*2
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Operation button
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
All stop
AC operation
All stop
Air purifying operation
AC + Air purifying operation
Louver*1
Cooling position
Follows to AC operation
Fan speed *2
AUTO, L, L+, M, M+, H
Follows to AC operation
* When the previous operation was the
operation of air condi air
purifier, an operation of air conditioner
+ air purifier starts by pushing AC
button on the remote controller.
(Operation of air condi air
purifier is stored in memory.)
*1
Swing is available
*2
Fan speed is Fan Auto mode varies
in order, (M + 1)
→
(L)
→
(L–)
→
(SL).
Summary of Contents for RAS-3M23GACV-E
Page 99: ... 99 MCC 1438 ...
Page 100: ... 100 MCC 818 ...