– 24 –
FILE NO. SVM-06017
8-2. Installation Diagram of Indoor and Outdoor Units
Shield
pipe
Air filte
r
Electric parts cover
Hook
(Atta
ch to
the fr
ont p
anel) (A
ttach
to th
e air filte
r)
2
Wireless remote
control
65 mm or more
170 m
m
or m
ore
600 mm or more
100 mm
or more
600 m
m o
r more
6
Bio-enzyme & Gingko filter
4
Remote control holder
Vinyl tape
Apply after
carrying out a
drainage test.
Saddle
Hook
170 m
m
or m
ore
The auxiliary piping can be
connected the left, rear left,
rear right or bottom.
Right
Rear
Bottom
Insulate the refrigerant
pipes separately with
insulation, not together.
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
600 mm or more
Extension
drain hose
(Not available,
provided by
1
Installation
plate
100 mm or more
Wall
Left
Rear left
6 mm thick heat resisting
polyethylene foam
Loop the connective cable
(about 100 mm in diameter
and 300 – 350 mm long).
Do not allow the drain hose
to get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping hole
sloped slightly
5
Sasa-Zeolite Vitamin C filter
8
Pan head wood screw
installer)
Fig. 8-2-1
Bef
ore installing the
wireless remote control
•
With the remote control cover
open, load the batteries supplied
correctly, observing their polarity.
2
Wireless remote control
3
Batteries
Cover