– 9 –
FILE NO. SVM-06017
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
4-2. Outdoor Unit (RAS-30N2A2B)
No.
Parts name
Type
Specifications
Output (Rated) 2
3
00 W, 2 poles, 1 phase, 2
08/230
V, 60 Hz
1 Compressor
NH47NAHT
Winding resistance (
Ω
) C-R C-S
(at 25°C)
0.52
1.28
Output (Rated) 70 W, 6 poles, 1 phase, 220 V, 60 Hz
Winding resistance (
Ω
)
Red-Black
White-Black
2
Fan motor (for outdoor)
(at 20°C)
40.8
84.8
3
Running capacitor
451355
L
AC 450 V,
3.5
µ
F
(for fan motor)
4
Running capacitor
RS44B606U0220S
AC 440 V,
6
0
µ
F
(for compressor)
5
Magnetic contactor
A35
220 V, 60 Hz
STF-200-70K
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) ICF-340-30-2 DC 310-340V, 30W
2
Thermo sensor (TA-sensor)
———
10 k
Ω
at 25
°
C
3 Switchins transformer (T01) SWT-77 Output DC 7V, 12Va and 12Vb
4 Microcontroller TMP87CM40ANG 6G60
5
Heat exchanger sensor
———
10 k
Ω
at 25
°
C
(TC-sensor)
6
Line filter (L01)
SS11V-R07190
19 mH, AC 0.7 A
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C03) EKMH451VSN121MQ35S 120
µ
F, 450 V
9
Fuse (F01)
TSCR
T6.3 A, 250 V
10 Switching IC (IC01) MA8920 5 A, 900 V
11 Varistor (R09, R10) 15G561K 560 V
12 Resistor (R01) RF-5TK4R8 1.8
Ω
, 5 W
13 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V