<
Cooling / 230V >
・
The above specification values are those under the conditions that the indoor DB/WB=27/19
℃
and the outdoor DB/WB=35/–
℃
.
Total
A
B
C
Σ
kBTU
A
B
C
Cooling capacity
(kW)
Power consumption
(W)
Operating current
(A)
3 units
05
05
05
15
1.50
1.50
1.50
4.5
1130
5.23
(
2.4
-
6.3 ) (
400
- 1890 ) ( 2.22
-
8.58
)
07
05
05
17
2.00
1.50
1.50
5.0
1390
6.43
(
2.4
-
6.4 ) (
400
- 1890 ) ( 2.22
-
8.58
)
10
05
05
20
2.46
1.37
1.37
5.2
1530
7.08
(
2.4
-
6.5 ) (
400
- 1890 ) ( 2.22
-
8.58
)
13
05
05
23
2.87
1.16
1.16
5.2
1210
5.60
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
05
05
26
3.12
1.04
1.04
5.2
1200
5.55
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
07
07
05
19
1.89
1.89
1.42
5.2
1560
7.22
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
10
07
05
22
2.26
1.68
1.26
5.2
1220
5.64
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
07
05
25
2.67
1.44
1.08
5.2
1410
6.52
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
07
05
28
2.93
1.30
0.98
5.2
1190
5.50
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
10
10
05
25
2.03
2.03
1.13
5.2
1210
5.60
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
10
05
28
2.44
1.78
0.99
5.2
1200
5.55
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
10
05
31
2.69
1.61
0.90
5.2
1190
5.50
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
13
05
31
2.16
2.16
0.88
5.2
1180
5.46
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
13
05
34
2.41
1.98
0.80
5.2
1170
5.41
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
07
07
07
21
1.74
1.73
1.73
5.2
1220
5.62
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
10
07
07
24
2.17
1.52
1.52
5.2
1210
5.57
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
07
07
27
2.50
1.35
1.35
5.2
1200
5.53
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
07
07
30
2.78
1.21
1.21
5.2
1190
5.48
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
10
10
07
27
1.93
1.93
1.34
5.2
1200
5.53
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
10
07
30
2.25
1.73
1.21
5.2
1190
5.48
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
10
07
33
2.52
1.58
1.10
5.2
1180
5.44
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
13
07
33
2.05
2.05
1.09
5.2
1180
5.44
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
13
07
36
2.31
1.88
1.01
5.2
1170
5.39
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
10
10
10
30
1.74
1.73
1.73
5.2
1190
5.48
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
10
10
33
2.06
1.58
1.58
5.2
1180
5.44
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
16
10
10
36
2.31
1.44
1.44
5.2
1170
5.39
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
13
13
10
36
1.88
1.88
1.45
5.2
1170
5.39
(
2.4
-
6.5 ) (
400
- 1950 ) ( 2.22
-
8.85
)
Operating
status
Indoor unit
Unit capacity (kW)
FILE NO. SVM-18020
-1
-
2
1 -