FILE NO. SVM-04032
– 27 –
5-6. RAS-24UFP-E3 / RAS-24UA-E3
RAS-24UFPX3 / RAS-24UAX3
Standard
0.4
11.0
High
27/19
35/24
Cooling High temperature 0.7 12.0 High 32/23 43/26
Low temperature
0.3
1.0
Low
21/15
21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Evaporator
Indoor unit
Multi blade fan
Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
∅
2.0x650
S
Dryer
2JS386D5BB02
O.D.:6.35 mm
Packed valve
(
∅
15.88 )
Packed valve
(∅
6.35)
0.49m
(Connecting pipe)
∅
6.35 mm
T
P
Refrigerant
R-22 1.80kg
Mark ( ) means check points of Gas Leak
O.D.:15.88 mm
0.39m
(Connecting pipe)
∅
15.88 mm
∅
15.88 mm
0.39m
(Flexible pipe)
RAS-24UFPX3-T / RAS-24UAX3-T
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.