8-3. Installation
8-3-1. Optional installation parts
<Fixing bolt arrangement of outdoor unit>
RAS-24UAH-E4, RAS-24UA-E4, RAS-24UAX4, RAS-24UA-AR4, RAS-24UAX3-T1, RAS-18UAX4-T2
Fig. 8-3-1
RAS-18UAH-E4 RAS-18UA-E4, RAS-18UAX4, RAS-18UA-AR4
Fig. 8-3-2
Fig. 8-3-3
•
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
•
Use
∅
8 mm or
∅
10 mm anchor bolts and nuts.
•
If it is necessary to drain the defrost water, attach drain nipple 9 to the bottom plate of the outdoor unit
before installing it.
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
Refrigerant piping
Liquid side :
∅
6.35 mm
Gas side :
∅
12.70 mm (18 series except RAS-18NKDX4-T2 / RAS-18UAX4-T2)
:
∅
15.88 mm (24 series and RAS-18NKDX4-T2 / RAS-18UAX4-T2)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Air inlet
Drain outlet
600 mm