– 16 –
FILE NO. SVM-05016
4. SPECIFICATION OF ELECTRICAL PARTS
4-2. Outdoor Unit (RAS-24UAH-E4)
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200
−
240V, 31W
2
Thermo sensor (TA-sensor)
———
10 k
Ω
at 25
°
C
3 Micro Power Module (M01)
µ
RM1260V DC 390 V, Secondary DC 12 V
4
Microcontroller
TMP87CM40AN
5
Heat exchanger sensor
———
10 k
Ω
at 25
°
C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7
Diode (DB01)
D3SBA60
4 A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 4.7
µ
F, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6
Ω
, 2 W
12 Louver motor
MP35EA12
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
4-1.
Indoor Unit (RAS-24NKHD-E4, RAS-18NKHD-E4)
No.
Parts name
Type
Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor 2JS386D5BB02 Winding resistance (
Ω
) C-R C-S
(at 20
°
C) 0.886 1.979
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2
Fan motor (for outdoor)
KFG6-71SB5P-T1
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
64.4
127.4
3
Running capacitor
451355L AC 450 V, 3.5
µ
F
(for fan motor)
4
Running capacitor
BUM44X6005C AC 440 V, 60
µ
F
(for compressor)
5
Solenoid coil
VHV (STF)
AC 220 – 240 V
(for 4-way valve)
6
Thermo sensor
TE / TD
10 k
Ω
at 25
°
C / 50 k
Ω
at 25
°
C
7 Magnetic contactor
A35
220
−
240
V, 50 Hz
8 Transformer TT-05 220 – 240 V
9
Microcontroller
TMP47C840N
10
Varistor (R73, R74, R86)
15G471K
470 V
11
Fuse (F01)
MT3
T6.3 A, 250 V